06 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Serial Bus Eye-diagram and Pulse Mask Testing  
The following ARINC 429 mask/pulse test files are available:  
– 100 kbps Eye Test  
– 100 kbps 1’s Pulse Test  
– 100 kbps 0’s Pulse Test  
– 100 kbps Null Level Test  
– 12.5 kbps Eye Test  
– 12.5 kbps 1’s Pulse Test  
– 12.5 kbps 0’s Pulse Test  
– 12.5 kbps Null Level Test  
For additional information about eye-diagram mask testing on  
CAN, FlexRay, MIL-STD 1553, and ARINC 429 signals, refer to the  
application notes listed at the end of this document.  
Figure 9. ARINC 429 100 kbps eye-diagram mask test.  
Automated Physical Layer Conformance  
Testing  
To perform USB 2.0 signal quality testing based on USB-IF  
compliance standards, Keysight offers the DSOX4USBSQ or  
DSOX6USBSQ options on InfiniiVision 4000 or 6000 X-Series  
oscilloscopes. Figure 10 shows an example of the USB 2.0  
real-time eye test. Also included with this option is complete  
signal quality test report generation in HTML format. To see the  
complete list of supported tests, refer to the DSOX4USBSQ/  
DSOX6USBSQ signal quality test option data sheet listed at the  
ended of this document.  
To perform physical layer conformance testing on the differential  
FlexRay bus, Keysight provides a PC-based software package  
that you can download from Keysight’s website at no additional  
charge. If the InfiniiVision X-Series scope is licensed with the  
FlexRay, mask test, and segmented memory, you can perform  
automated physical layer tests at either receiver input or  
Figure 10. USB 2.0 signal quality eye test based on USB-IF physical layer  
compliance standards.  
transmitter output test points. Figure 10 shows an example of the  
generated report from a signal integrity voting test on a 10-Mbs  
isolated “1” pulse. The test report includes comprehensive pass/  
fail and margin analysis based on published specifications.  
Refer to the tables in the Specifications/Characteristics section  
of this document on page 17 to see the entire list of 33 available  
FlexRay tests that can be selected and performed using the  
FlexRay physical layer conformance test software package.  
Figure 11. FlexRay signal integrity voting test performed on an isolated  
“1” bit.  