24 | Keysight | InfiniiVision 4000 X-Series Oscilloscopes - Data Sheet
Oscilloscope Experience Redefined:
Configuring Your InfiniiVision 4000 X-Series Oscilloscope
Step 1. Choose your bandwidth and number of channels
InfiniiVision 4000 X-Series scopes oscilloscopes
4022A
200 MHz
≤ 1.75 ns
2
4024A
4032A
350 MHz
≤ 1 ns
2
4034A
4052A
500 MHz
≤ 700 ps
2
4054A
4104A
1 GHz
≤ 450 ps
4
4154A
1.5 GHz
≤ 300 ps
4
Bandwidth 1 (–3 dB)
Calculated rise time (10 to 90%)
Input channels
DSOX
MSOX
4
4
4
2 + 16
4 + 16
2 + 16
4 + 16
2 + 16
4 + 16
4 + 16
4 + 16
1� For example, if you chose 1 GHz, 4+16 channels, the model number will be MSOX4104A.
Step 2. Tailor your oscilloscope with integrated capabilities and measurement applications to save
time and money. After purchase upgrade model numbers are listed below (values in parentheses are
factory-installed option numbers)
Description
Model number
Enables all software options listed below
Serial protocols
DSOX4APPBNDL
Embedded serial triggering and decode (I²C, SPI)
Computer serial triggering and decode (RS232/UART)
USB 2.0 Full/Low Speed serial triggering and decode
USB 2.0 Hi-Speed serial triggering and decode
Automotive serial triggering and decode CAN/CAN-FD/CAN-dbc/LIN/LIN symbolic
FlexRay serial triggering and decode
Single edge nibble transmission triggering and decode (SENT)
CXPI serial triggering and decode
Audio serial triggering and decode (I²S)
Aerospace and defence serial triggering and decode (MIL-STD 1553, ARINC 429)
User-definable Manchester/NRZ triggering and decode
USB PD serial triggering and decode
DSOX4EMBD(-EMB)
DSOX4COMP(-CMP)
DSOX4USBFL(-USF)
DSOX4USBH(-U2H) 1
DSOX4AUTO(-AMS)
DSOX4FLEX(-FLX)
DSOX4SENSOR(-SEN)
DSOX4CXPI(-CXP)
DSOX4AUDIO(-SND)
DSOX4AERO(-AER)
DSOX4NRZ
DSOX4UPD
Measurement applications
Dual-channel WaveGen 20 MHz arbitrary/function generator
Power analysis application
Frequency Response Analysis (FRA)
DSOX4WAVEGEN2(-WAV)
DSOX4PWR(-PWR)
DSOX4FRA
Mask limit testing
Enhanced video/TV application package
USB 2.0 signal quality test option
NFC trigger and automated test software
Productivity tools
DSOX4MASK(-MSK)
DSOX4VID(-VID)
DSOX4USBSQ(-U2Q) 2
DSOX4NFC
Infiniium Offline oscilloscope analysis software
User-definable Application (UDA) PC-based test automation software
Vector signal analyzer software (version 16 and higher)
BenchVue Software
N8900A
N5467B/C
89601B
BV0004B
1� DSOX4USBH is only available for 1 GHz and 1.5 GHz models.
2. USB 2.0 hi-speed tests require 1.5 GHz models.
See page 35 for more detailed upgradability and installation process information.