 浏览型号DSO/MSO9000A-500的Datasheet PDF文件第18页浏览型号DSO/MSO9000A-500的Datasheet PDF文件第19页浏览型号DSO/MSO9000A-500的Datasheet PDF文件第20页浏览型号DSO/MSO9000A-500的Datasheet PDF文件第21页浏览型号DSO/MSO9000A-500的Datasheet PDF文件第23页浏览型号DSO/MSO9000A-500的Datasheet PDF文件第24页浏览型号DSO/MSO9000A-500的Datasheet PDF文件第25页浏览型号DSO/MSO9000A-500的Datasheet PDF文件第26页  
22 | Keysight | Infiniium 9000 Series Oscilloscopes - Data Sheet  
Infiniium 9000 Series Performance Characteristics (Continued)  
Acquisition  
9104, 9254, 9404  
9064  
Maximum real-time sample rate  
Memory depth per channel  
Standard  
Option 50M  
Option 100  
4 ch x 10 GS/s or 2 ch x 20 GS/s  
4 ch x 5 GSa/s or 2 ch x 10 GSa/s  
20 Mpts on 4 channels, 40 Mpts on 2 channels  
50 Mpts on 4 channels, 100 Mpts on 2 channels  
100 Mpts on 4 channels, 200 Mpts on 2 channels  
200 Mpts on 4 channels, 400 Mpts on 2 channels  
Option 200  
Option 500  
500 Mpts/250 Mpts on 4 channels, 1 Gpts/500 Mpts on 2 channels (single/repetitive mode)  
Sampling modes  
Real-time  
Real-time with peak detect  
Real-time with high resolution (user selectable to 9-, 10-, 11-, or 12-bits of resolution)  
Real-time with roll mode (200 ms to 20 sec.)  
Equivalent-time (1.0 ps fine interpolator resolution yields a maximum effective sample rate of 1,000 GSa/s)  
Segmented memory (1 ps time stamp resolution between segments)  
Maximum time between triggers is 562,950 seconds (6.5 days)  
Re-arm time (minimum time between trigger events) is 4.5 μs with analog channels, 5.8 μs with digital channels on  
Memory depth:  
Max # of segments:  
Filters  
20 M  
4096  
50 M  
8192  
100 M  
16384  
200 M  
32768  
500 M  
65536  
1 G  
131072  
2 G  
131072  
Acquisition: Digital channels  
Maximum real time sample rate  
Maximum memory depth per channel  
Minimum width glitch detection  
Trigger: Scope channels  
Trigger sources  
2 GSa/s  
128/64 Mpts with 2 GSa/s. 64/32 Mpts with sampling < 2 GSa/s (single/repetitive mode)  
2 ns  
Channel 1, channel 2, channel 3, channel 4, aux, and line  
Sensitivity  
1 MΩ input, edge trigger  
50 Ω  
DC to 500 MHz: 0.6 div  
DC to 2 GHz, 0.5 div  
2 GHz to 4 GHz: 1.0 div  
DC to 700 MHz: 300 mVp-p  
Auxiliary  
Trigger level range  
Channel 1, 2, 3 or 4  
Auxiliary  
Sweep modes  
Display jitter (displayed trigger jitter) 1, 2  
± 4 div from center screen (50 Ω)  
± 8 div from center screen with max of ± 8 V (1 MΩ)  
± 5 V (50 Ω up to 500 MHz with at least 500 mV signal swing)  
Auto, triggered, single  
9064 .50  
9104 .35  
9254 .50  
9404 .40  
Trigger holdoff range  
Trigger actions  
100 ns to 10 s fixed and random  
Specify an action to occur, and the frequency of the action, when a trigger condition occurs  
Actions include: e-mail on trigger and execute “multipurpose” user settings  
Trigger coupling  
1 MΩ: DC, AC, (10 Hz) low frequency reject (50 kHZ high pass filter), high frequency reject (50 kHz low pass  
filter)  
1� Internal edge trigger mode� Trigger threshold = fixed voltage at 50% level� The slew rate independent value in the formula represents the traditional trigger  
jitter�  
2� Display jitter example� At 100 mV/div typical noise values are 3�2 mV RMS for 9404 models, 2�5 mV RMS for 9254A models, and 2�4 mV RMS for 9104A  
models� For slew rate of 500 mVpp sin wave with frequency equal to max analog bandwidth of each model, typical display jitter is �95 ps RMS for 9404A  
models, �97 ps for 9254A models, and 1�7 ps RMS for 9104A models�  