25 | Keysight | CX3300 Series Device Current Waveform Analyzer - Data Sheet  
Table 23. CX1102A characteristics overview  
Range  
Noise (rms) 3  
Maximum  
bandwidth  
(-3 dB) 4  
2
RIN  
Secondary  
Primary channel  
Secondary  
Primary channel  
channel  
channel  
1 A  
20 mA  
2 mA  
2 mA  
0.2 mA  
20 μA  
8 μA 5  
2 μA  
20 μA  
410 mΩ (typ)  
550 mΩ (max)  
100 MHz  
200 mA  
3 μA  
500 nA  
400 nA 5  
200 nA  
40 nA 5  
500 kHz  
90 kHz 5  
500 kHz  
25 kHz 5  
Current  
measurement 1  
50 Ω (typ)  
77 Ω (max)  
20 mA  
2 mA  
200 μA  
20 μA  
50 Ω (typ)  
77 Ω (max)  
1 μA 5  
1. Sensor Head used to measure the characteristics: CX1203A.  
2. The slide switch of CX1203A to be set to “0 Ω”.  
3. 20 MHz noise bandwidth measured with mainframe.  
4. Standalone bandwidth. The effective measurement bandwidth when connected to mainframe can be estimated by the following equation.  
1
BWeffective  
=
1
1
BWmainframe  
BWsensor  
2
2
+
5. The sensor built-in low pass filter is ON.  
Table 24. CX1102A DC measurement accuracy 1  
Standalone  
23 ±5 ºC  
With mainframe  
23 ±5 ºC  
Range  
TUSERCAL ±3 ºC, 24 hrs 2  
± (1.8% + 0.4%)  
± (0.6% + 0.4%)  
± (0.6% + 0.4%)  
± (0.6% + 0.9%)  
± (0.6% + 0.3%)  
± (0.7% + 0.3%)  
± (0.6% + 0.4%)  
± (0.7% + 0.9%)  
1 A primary  
± (2% + 2%) **  
± (2% + 2%) **  
± (2% + 2%) **  
± (2% + N/A) **  
± (2% + 2%) **  
± (2% + 2%) **  
± (2% + 2%) **  
± (2% + N/A) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
± (2.7% + N/A) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
± (2.7% + N/A) **  
200 mA primary  
20 mA secondary  
2 mA secondary  
20 mA primary  
2 mA primary  
Gain [% of readings] +  
Offset [% of range]  
200 μA secondary  
20 μA secondary  
1. Accuracy is defined at VCM = 0 V (zero Common Mode input voltage at either +IIN or -IIN). Add 0.9% typical to Offset error for Vcm up to 12 V. “Readings”  
means measured data by mainframe. DC measurement condition: 20 ms averaged.  
2. After executing the User Calibration with mainframe. Supplemental characteristics.  