31 | Keysight | Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet
Ordering Information (Continued)
External clock recovery solutions 4
N1076A electrical clock recovery
86108B options
86108B-LBW Dual 35 GHz electrical channels
86108B-HBW Dual 50 GHz electrical channels
86108B-216
86108B-232
86108B-300
86108B-400
86108B-PTB
86108B-JSA
N1076A-216
N1076A-232
N1076A-JSA
Clock recovery range: 50 MBd to 16 GBd
Clock recovery range: 50 MBd to 32 GBd
Jitter spectrum analysis
Clock recovery 50 Mb/s to 16 Gb/s
Clock recovery 50 Mb/s to 32 Gb/s
Adjustable loop bandwidth/peaking
Auxiliary clock recovery input
Integrated precision timebase
Jitter spectrum analysis and software clock recovery
emulation
N1076B electrical clock recovery
N1076B-216
N1076B-232
N1076B-264
Clock recovery range: 125 MBd to 16 GBd
Clock recovery range: 125 MBd to 32 GBd
Clock recovery range: 125 MBd to 64 GBd (56 GBd for
PAM4 signals)
N1076B-EVA
N1076B-JSA
N1077A optical/electrical clock recovery
N1077A-216
N1077A-232
N1077A-SMS
N1077A-SXT
N1077A-JSA
Integrated variable equalizers (mandatory option)
Jitter Spectrum Analysis
86108B-A23
86108B-CA2
86108B-CA3
86108B-DC2
86108B-DC3
86108B-PT2
Two adapters, 2.4 mm (f) to 3.5 mm (f)
Matched cable pair, 2.4 to 2.4 mm, 24 inch
Matched cable pair, 3.5 to 3.5 mm, 18 inch
Two DC blocks, 2.4 mm, 16 V, 50 kHz to 50 GHz
Two DC blocks, 3.5 mm, 16 V, 50 kHz to 26.5 GHz
Two 2.4 mm phase trimmers for ext. skew adjustment
Phase trimmers
Clock recovery range: 50 MBd to 16 GBd
Clock recovery range: 50 MBd to 32 GBd
Internal SM and MM splitters
No splitter (supplied by user)
Jitter spectrum analysis
Nominal impedance
Frequency range
N1078A optical/electrical clock recovery
Insertion loss (at f max)
N1078A-216
N1078A-232
N1078A-264
N1078A-S50
N1078A-SXT
N1078A-JSA
N1078A-EVA
Clock recovery range: 125 MBd to 16 GBd
Time delay
Connectors
Clock recovery range: 125 MBd to 32 GBd
Clock recovery range: 125 MBd to 64 GBd
Internal 50-50 SM optical splitter
No splitter (splitter supplied by user)
Jitter spectrum analysis
86108B-PT3
Two 3.5 mm phase trimmers for ext. skew adjustment
Phase trimmers
Nominal impedance
Frequency range
Integrated variable equalizers in electrical input path
(mandatory option)
Insertion loss (at f max)
Time delay
Connectors
Precision waveform analyzer module 1, 3
Dual electrical channel module with integrated clock recovery and
precision timebase.
1. 86100D-ETR is recommended when;
a. More than 1 TDR module is connected to the same DUT.
b. Using a DCA module equipped with a rear-panel trigger circuit.
Examples include 54754A, 83496x, and 86108A/B modules. If
operating these modules in an 86100D with Option STR, an external
cable (such as P/N 5062-6690) must be connected from the module’s
front panel trigger/clock output to the 86100D’s trigger input.
2. Requires 86100D mainframe (not compatible with 86100A/B/C).
3. This module is not compatible with the 86100A and 86100B DCA
mainframes. If you want to upgrade older DCAs, contact Keysight
Technologies to discuss current trade-in deals.
86108A-100
Dual 32 GHz electrical channels, integrated clock
recovery (50 Mb/s to 14.2 Gb/s) with integrated
precision timebase
Two 3.5 mm phase trimmers for skew adjustment
Two precision 3.5 mm 18 inch cables
Auxiliary clock recovery Input
86108A-001
86108A-002
86108A-400
4. Supports both DCA-X and DCA-M platforms. For detailed
N1076A/N1077A specifications, refer to the data sheet located at
www.keysight.com/find/N1077A. Standalone clock recovery instruments
are controlled via a USB connection to an 86100D DCA-X mainframe or a
user-supplied PC running N1010A FlexDCA software.
5. Included with each of these TDR modules is a TDR trigger cable, two 50 Ω