MB & JB Series
Bulletin I2715 rev. E 08/97
150
Maximum Allowable Case Temperature (°C)
1000
Instantaneous Forward Current (A)
36MB..A Series
35MB..A Series
T
J
= 25°C
T
J
= 150°C
130
100
110
180°
(Rect)
90
180°
(Sine)
70
10
36MB..A Series
35MB..A Series
1
0.5
1
1.5
2
2.5
3
3.5
50
0
5
10
15
20
25
30
35
40
Average Forward Current (A)
Instantaneous Forward Voltage (V)
Fig. 11 - Current Ratings Chracteristics
Fig. 12 - Forward Voltage Drop Characteristics
80
Maximum Average Forward Power Loss (W)
36MB..A Series
35MB..A Series
T = 150°C
J
60
180°
(Sine)
180°
(Rect)
40
3 K/
W
4 K/W
R
th
SA
=
1K
/W
0.
7
K/
W
2K
/W
-D
el
ta
R
20
5 K/W
7 K/W
0
0
5
10
15
20
25
30
35
0
25
50
75
100
125
150
Average Forward Current (A)
Maximum Allowable Ambient Temperature (°C)
Fig. 13 - Total Power Loss Characteristics
Peak Half Sine W
ave Forward Current (A)
400
350
300
250
200
150
100
1
At Any Rated Load Condition And With
Rated V
RRM
Applied Following Surge.
Initial T
J
= 150°C
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
Peak Half Sine W
ave Forward Current (A)
450
500
450
400
350
300
250
200
150
100
0.01
Maximum Non Repetitive Surge Current
Versus Pulse Train Duration.
Initial T
J
= 150°C
No Voltage Reapplied
Rated V
RRM
Reapplied
36MB..A Series
35MB..A Series
10
100
36MB..A Series
35MB..A Series
0.1
Pulse Train Duration (s)
1
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Fig. 14 - Maximum Non-Repetitive Surge Current
Fig. 15 - Maximum Non-Repetitive Surge Current
6
www.irf.com