Intel® IXP42X Product Line of Network Processors and IXC1100 Control Plane Processor
Table 56.
Motorola* Multiplexed Mode Values
Symbol
Talepulse
Parameter
Min. Max. Units
Notes
Pulse width of EX_ALE (ADDR is valid at the rising edge of
EX_ALE)
1
4
Cycles
1, 7
Tale2addrhold Valid address hold time after from falling edge of EX_ALE
1
1
1
1
1
1
4
Cycles 1, 2, 7
Tdval2valds
Tdspulse
Write data valid prior to EXP_MOT_DS_N falling edge
Pulse width of the EXP_MOT_DS_N
Cycles
Cycles
Cycles
Cycles
ns
3, 7
4, 7
5, 7
7
16
4
Tdholdafterds Valid data after the rising edge of EXP_MOT_DS_N
Tale2valcs
Trdsetup
Trdhold
Valid chip select after the falling edge of EX_ALE
4
Data valid required before the rising edge of EXP_MOT_DS_N 15
Data hold required after the rising edge of EXP_MOT_DS_N
0
ns
Time needed between successive accesses on expansion
interface.
Trecov
1
16
Cycles
6
Notes:
1.
The EX_ALE signal is extended from 1 to 4 cycles based on the programming of the T1 timing
parameter. The parameter Tale2addrhold is fixed at 1 cycle.
2.
3.
4.
5.
6.
Setting the address phase parameter (T1) will adjust the duration that the address appears to the external
device.
Setting the data setup phase parameter (T2) will adjust the duration that the data appears prior to a
data strobe (read or write) to an external device.
Setting the data strobe phase parameter (T3) will adjust the duration that the data strobe appears (read
or write) to an external device. Data will be available during this time as well.
Setting the data hold strobe phase parameter (T4) will adjust the duration that the chip selects,
address, and data (during a write) will be held.
Setting the recovery phase parameter (T5) will adjust the duration between successive accesses on
the expansion interface.
7.
8.
One cycle is the period of the Expansion Bus clock.
Clock to output delay for all signals will be a maximum of 15 ns for devices requiring operation in
synchronous mode.
9.
Timing tests were performed with a 70-pF capacitor to ground.
Datasheet
March 2005
Document Number: 252479, Revision: 005
109