2–10
Chapter 2: MAX II Architecture
Logic Elements
The other two LUTs use the data1 and data2 signals to generate two possible carry-out
signals: one for a carry of 1 and the other for a carry of 0. The carry-in0 signal acts
as the carry-select for the carry-out0output and carry-in1acts as the carry-
select for the carry-out1output. LEs in arithmetic mode can drive out registered
and unregistered versions of the LUT output.
The dynamic arithmetic mode also offers clock enable, counter enable, synchronous
up/down control, synchronous clear, synchronous load, and dynamic
adder/subtractor options. The LAB local interconnect data inputs generate the
counter enable and synchronous up/down control signals. The synchronous clear
and synchronous load options are LAB-wide signals that affect all registers in the
LAB. The Quartus II software automatically places any registers that are not used by
the counter into other LABs. The addnsub LAB-wide signal controls whether the LE
acts as an adder or subtractor.
Figure 2–8. LE in Dynamic Arithmetic Mode
LAB Carry-In
Carry-In0
sload
(LAB Wide) (LAB Wide)
Register chain
connection
sclear
aload
(LAB Wide)
Carry-In1
addnsub
(LAB Wide)
(1)
ALD/PRE
data1
data2
data3
LUT
ADATA
D
Row, column, and
direct link routing
Q
LUT
LUT
LUT
Row, column, and
direct link routing
ENA
CLRN
clock (LAB Wide)
ena (LAB Wide)
aclr (LAB Wide)
Local routing
LUT chain
connection
Register
chain output
Register Feedback
Carry-Out0 Carry-Out1
Note to Figure 2–8:
(1) The addnsubsignal is tied to the carry input for the first LE of a carry chain only.
Carry-Select Chain
The carry-select chain provides a very fast carry-select function between LEs in
dynamic arithmetic mode. The carry-select chain uses the redundant carry calculation
to increase the speed of carry functions. The LE is configured to calculate outputs for a
possible carry-in of 0 and carry-in of 1 in parallel. The carry-in0and carry-in1
signals from a lower-order bit feed forward into the higher-order bit via the parallel
carry chain and feed into both the LUT and the next portion of the carry chain. Carry-
select chains can begin in any LE within an LAB.
MAX II Device Handbook