Page 10
Electrical Characteristics
Table 9 lists the Arria V OCT without calibration resistance tolerance to PVT changes.
Table 9. OCT Without Calibration Resistance Tolerance Specifications for Arria V Devices
Resistance Tolerance
Symbol
Description
Conditions (V)
VCCIO = 3.0 and 2.5
VCCIO = 1.8 and 1.5
VCCIO = 1.2
Unit
%
I3, C4
I5, C5
C6
Internal series termination
without calibration
(25-Ωsetting)
25-ΩRS
30
30
35
30
30
40
40
Internal series termination
without calibration
(25-Ωsetting)
25-ΩRS
25-ΩRS
50-ΩRS
50-ΩRS
40
50
40
40
40
50
40
40
%
Internal series termination
without calibration
(25-Ωsetting)
%
Internal series termination
without calibration (50-Ω
setting)
V
CCIO = 3.0 and 2.5
%
Internal series termination
without calibration
(50-Ωsetting)
VCCIO = 1.8 and 1.5
%
Internal series termination
without calibration
(50-Ωsetting)
50-Ω RS
VCCIO = 1.2
VCCIO = 2.5
35
25
50
40
50
40
%
%
Internal differential
termination (100-Ωsetting)
100-Ω RD
Use Table 10 to determine the OCT variation after power-up calibration and
Equation 1 to determine the OCT variation without recalibration.
Equation 1. OCT Variation Without Recalibration (1), (2), (3), (4), (5), (6)
dR
dT
dR
dV
⎛
⎞
------
-------
× ΔV〉
ROCT = RSCAL 1 + 〈
× ΔT〉 〈
⎝
⎠
Notes to Equation 1:
(1) The ROCT value calculated from Equation 1 shows the range of OCT resistance with the variation of temperature and
VCCIO
.
(2) RSCAL is the OCT resistance value at power-up.
(3) ΔT is the variation of temperature with respect to the temperature at power up.
(4) ΔV is the variation of voltage with respect to the VCCIO at power up.
(5) dR/dT is the percentage change of RSCAL with temperature.
(6) dR/dV is the percentage change of RSCAL with voltage.
Arria V GX, GT, SX, and ST Device Datasheet
December 2013 Altera Corporation