 浏览型号5AGXFB3K6F31C5N的Datasheet PDF文件第6页浏览型号5AGXFB3K6F31C5N的Datasheet PDF文件第7页浏览型号5AGXFB3K6F31C5N的Datasheet PDF文件第8页浏览型号5AGXFB3K6F31C5N的Datasheet PDF文件第9页浏览型号5AGXFB3K6F31C5N的Datasheet PDF文件第11页浏览型号5AGXFB3K6F31C5N的Datasheet PDF文件第12页浏览型号5AGXFB3K6F31C5N的Datasheet PDF文件第13页浏览型号5AGXFB3K6F31C5N的Datasheet PDF文件第14页  
Page 10  
Electrical Characteristics  
Table 9 lists the Arria V OCT without calibration resistance tolerance to PVT changes.  
Table 9. OCT Without Calibration Resistance Tolerance Specifications for Arria V Devices  
Resistance Tolerance  
Symbol  
Description  
Conditions (V)  
VCCIO = 3.0 and 2.5  
VCCIO = 1.8 and 1.5  
VCCIO = 1.2  
Unit  
%
I3, C4  
I5, C5  
C6  
Internal series termination  
without calibration  
(25-Ωsetting)  
25-ΩRS  
30  
30  
35  
30  
30  
40  
40  
Internal series termination  
without calibration  
(25-Ωsetting)  
25-ΩRS  
25-ΩRS  
50-ΩRS  
50-ΩRS  
40  
50  
40  
40  
40  
50  
40  
40  
%
Internal series termination  
without calibration  
(25-Ωsetting)  
%
Internal series termination  
without calibration (50-Ω  
setting)  
V
CCIO = 3.0 and 2.5  
%
Internal series termination  
without calibration  
(50-Ωsetting)  
VCCIO = 1.8 and 1.5  
%
Internal series termination  
without calibration  
(50-Ωsetting)  
50-Ω RS  
VCCIO = 1.2  
VCCIO = 2.5  
35  
25  
50  
40  
50  
40  
%
%
Internal differential  
termination (100-Ωsetting)  
100-Ω RD  
Use Table 10 to determine the OCT variation after power-up calibration and  
Equation 1 to determine the OCT variation without recalibration.  
Equation 1. OCT Variation Without Recalibration (1), (2), (3), (4), (5), (6)  
dR  
dT  
dR  
dV  
------  
-------  
× ΔV〉  
ROCT = RSCAL 1 + 〈  
× ΔT〉 〈  
Notes to Equation 1:  
(1) The ROCT value calculated from Equation 1 shows the range of OCT resistance with the variation of temperature and  
VCCIO  
.
(2) RSCAL is the OCT resistance value at power-up.  
(3) ΔT is the variation of temperature with respect to the temperature at power up.  
(4) ΔV is the variation of voltage with respect to the VCCIO at power up.  
(5) dR/dT is the percentage change of RSCAL with temperature.  
(6) dR/dV is the percentage change of RSCAL with voltage.  
Arria V GX, GT, SX, and ST Device Datasheet  
December 2013 Altera Corporation