Boxed Processor Specifications  
Figure 7-5. Baseboard Power Header Placement Relative to Processor Socket  
7.3  
Thermal Specifications  
This section describes the cooling requirements of the fan heatsink solution used by the boxed  
processor.  
7.3.1  
Boxed Processor Cooling Requirements  
The boxed processor may be directly cooled with a fan heatsink. However, meeting the processor's  
temperature specification is also a function of the thermal design of the entire system, and  
ultimately the responsibility of the system integrator. The processor temperature specification is  
found in Chapter 5 of this document. The boxed processor fan heatsink is able to keep the  
processor temperature within the specifications (see Table 5-1) in chassis that provide good  
thermal management. For the boxed processor fan heatsink to operate properly, it is critical that the  
airflow provided to the fan heatsink is unimpeded. Airflow of the fan heatsink is into the center and  
out of the sides of the fan heatsink. Airspace is required around the fan to ensure that the airflow  
through the fan heatsink is not blocked. Blocking the airflow to the fan heatsink reduces the  
cooling efficiency and decreases fan life. Figure 7-6 and Figure 7-7 illustrate an acceptable  
airspace clearance for the fan heatsink. The air temperature entering the fan is required to be at or  
below 38 °C. Again, meeting the processor's temperature specification is the responsibility of the  
system integrator.  
Datasheet  
77