Package Mechanical Specifications  
3.2  
3.3  
Processor Component Keep-Out Zones  
The processor may contain components on the substrate that define component keep-  
out zone requirements. A thermal and mechanical solution design must not intrude into  
the required keep-out zones. Decoupling capacitors are typically mounted to either the  
topside or land-side of the package substrate. See Figure 9 and Figure 10 for keep-out  
zones. The location and quantity of package capacitors may change due to  
manufacturing efficiencies but will remain within the component keep-in.  
Package Loading Specifications  
Table 20 provides dynamic and static load specifications for the processor package.  
These mechanical maximum load limits should not be exceeded during heatsink  
assembly, shipping conditions, or standard use condition. Also, any mechanical system  
or component testing should not exceed the maximum limits. The processor package  
substrate should not be used as a mechanical reference or load-bearing surface for  
thermal and mechanical solution. The minimum loading specification must be  
maintained by any thermal and mechanical solutions.  
.
Table 20.  
Processor Loading Specifications  
Parameter  
Minimum  
Maximum  
Notes  
Static  
80 N [17 lbf]  
-
311 N [70 lbf]  
756 N [170 lbf]  
1, 2, 3  
1, 3, 4  
Dynamic  
NOTES:  
1.  
2.  
3.  
4.  
These specifications apply to uniform compressive loading in a direction normal to the  
processor IHS.  
This is the maximum force that can be applied by a heatsink retention clip. The clip must  
also provide the minimum specified load on the processor package.  
These specifications are based on limited testing for design characterization. Loading limits  
are for the package only and do not include the limits of the processor socket.  
Dynamic loading is defined as an 11 ms duration average load superimposed on the static  
load requirement.  
3.4  
Package Handling Guidelines  
Table 21 includes a list of guidelines on package handling in terms of recommended  
maximum loading on the processor IHS relative to a fixed substrate. These package  
handling loads may be experienced during heatsink removal.  
Table 21.  
Package Handling Guidelines  
Parameter  
Maximum Recommended  
Notes  
Shear  
Tensile  
Torque  
311 N [70 lbf]  
111 N [25 lbf]  
1, 4  
2, 4  
3, 4  
3.95 N-m [35 lbf-in]  
NOTES:  
1.  
2.  
3.  
4.  
A shear load is defined as a load applied to the IHS in a direction parallel to the IHS top  
surface.  
A tensile load is defined as a pulling load applied to the IHS in a direction normal to the  
IHS surface.  
A torque load is defined as a twisting load applied to the IHS in an axis of rotation normal  
to the IHS top surface.  
These guidelines are based on limited testing for design characterization.  