 浏览型号10AX115S2F45I1SG的Datasheet PDF文件第6页浏览型号10AX115S2F45I1SG的Datasheet PDF文件第7页浏览型号10AX115S2F45I1SG的Datasheet PDF文件第8页浏览型号10AX115S2F45I1SG的Datasheet PDF文件第9页浏览型号10AX115S2F45I1SG的Datasheet PDF文件第11页浏览型号10AX115S2F45I1SG的Datasheet PDF文件第12页浏览型号10AX115S2F45I1SG的Datasheet PDF文件第13页浏览型号10AX115S2F45I1SG的Datasheet PDF文件第14页  
A10-DATASHEET  
2015.12.31  
10  
DC Characteristics  
Symbol  
Description  
Condition  
Minimum (17)  
1.71  
Typical  
1.8  
Maximum (17)  
1.89  
Unit  
VCCIOREF_HPS  
VCCPLL_HPS  
HPS I/O pre-driver power supply  
V
V
HPS PLL analog voltage regulator  
power supply  
1.71  
1.8  
1.89  
Related Information  
Recommended Operating Conditions on page 4  
Provides the steady-state voltage values for the FPGA portion of the device.  
DC Characteristics  
The OCT variation after power-up calibration specifications will be available in a future release of the Arria 10 Device Datasheet.  
Supply Current and Power Consumption  
Altera offers two ways to estimate power for your design—the Excel-based Early Power Estimator (EPE) and the Quartus Prime PowerPlay Power  
Analyzer feature.  
Use the Excel-based EPE before you start your design to estimate the supply current for your design. The EPE provides a magnitude estimate of the  
device power because these currents vary greatly with the usage of the resources.  
The Quartus Prime PowerPlay Power Analyzer provides better quality estimates based on the specifics of the design after you complete place-and-  
route. The PowerPlay Power Analyzer can apply a combination of user-entered, simulation-derived, and estimated signal activities that, when  
combined with detailed circuit models, yield very accurate power estimates.  
Related Information  
PowerPlay Early Power Estimator User Guide  
Provides more information about power estimation tools.  
PowerPlay Power Analysis chapter, Quartus Prime Handbook  
Provides more information about power estimation tools.  
(17)  
This value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance requirements. Refer to the  
PDN tool for the additional budget for the dynamic tolerance requirements.  
Arria 10 Device Datasheet  
Send Feedback  