欢迎访问ic37.com |
会员登录 免费注册
发布采购

FIDO2100 参数 Datasheet PDF下载

FIDO2100图片预览
型号: FIDO2100
PDF下载: 下载PDF文件 查看货源
内容描述: fido2100 3端口工业以太网交换机DLR与IEEE 1588 [fido2100 3-Port Industrial Ethernet DLR Switch with IEEE 1588]
分类和应用: 以太网工业以太网
文件页数/大小: 84 页 / 2688 K
品牌: INNOVASIC [ INNOVASIC, INC ]
 浏览型号FIDO2100的Datasheet PDF文件第76页浏览型号FIDO2100的Datasheet PDF文件第77页浏览型号FIDO2100的Datasheet PDF文件第78页浏览型号FIDO2100的Datasheet PDF文件第79页浏览型号FIDO2100的Datasheet PDF文件第80页浏览型号FIDO2100的Datasheet PDF文件第81页浏览型号FIDO2100的Datasheet PDF文件第83页浏览型号FIDO2100的Datasheet PDF文件第84页  
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588  
Data Sheet  
April 10, 2013  
.
P2TxErrFrmCnt: This 16-bit counter reflects frames truncated with error during  
transmission on port 2.  
9.2.35 Beacon Generation Control Register  
Mnemonic  
type offset bits 15  
R/W 0xDC  
14  
13  
12  
11  
10  
0
9
0
8
0
7
0
6
0
5
0
4
0
3
2
1
0
BcnGenCntrl  
bgrst bge2 bge1 bite  
Power-up Defaults  
0
0
0
0
0
0
0
0
0
bite  
Beacon Interval Timer Enable. When this bit is set, beacon interval timer is  
enabled. It’s a periodic timer and when the interval expires, beacon generation  
is triggered if bge1/bge2 are set and the timer is restarted. In order to  
immediately trigger a beacon frame on ports, this bit should be reset and set.  
bge1  
bge2  
bgrst  
Beacon Generation Enable for Port 1. When this bit is set, DLR beacon  
frame generation is enabled on port 1. Frame sequence ID will be  
automatically generated.  
Beacon Generation Enable for Port 2. When this bit is set, DLR beacon  
frame generation is enabled on port 2. Frame sequence ID will be  
automatically generated.  
Beacon Generation Reset. When this bit is set, all beacon frame generation  
logic will be held in reset.  
9.2.36 Beacon Interval Register  
Mnemonic  
type offset bits 15  
R/W 0xDE  
14  
13  
0
12  
0
11  
0
10  
0
9
8
7
6
5
0
5
0
4
0
4
0
3
0
3
0
2
0
2
0
1
0
1
0
0
0
0
0
BcnIntrvl_Lo  
BeaconInterval[15:0]  
Power-up Defaults  
0
0
0
9
0
8
0
7
0
6
Mnemonic  
type offset bits 15  
R/W 0xE0  
14  
0
13  
0
12  
0
11  
0
10  
0
BcnIntrvl_Hi  
BeaconInterval[31:16]  
Power-up Defaults  
0
0
0
0
0
The Beacon Interval register consists of two 16-bit registers. It is a 32-bit counter that  
counts at 50MHz and is used to trigger beacon frame generation on port(s) when it is  
enabled and expires. See bite bit in Beacon Generation Control register for more details.  
82  
support@innovasic.com  
Document #: IA211111101-04  
UNCONTROLLED WHEN PRINTED OR COPIED  
1-505-883-5263  
1-888-824-4184  
 复制成功!