IA186ES/IA188ES  
Data Sheet  
8-Bit/16-Bit Microcontrollers  
November 15, 2011  
Table 14. Interrupt Types (Continued)  
Vector  
Table  
Address  
4ch  
24h  
28h  
Interrupt  
Type  
EOI  
Type  
08h  
Overall  
Priority  
2C  
Related  
Instructions  
Interrupt Name  
d,e  
13h  
Timer2 Interrupt  
Reserved  
09h  
0ah  
e
e
0ah  
0bh  
0ch  
0dh  
0eh  
0fh  
3
4
5
6
7
8
9
9
DMA0 Interrupt/INT5  
DMA1 Interrupt/INT6  
INT0 Interrupt  
INT1 Interrupt  
INT2 Interrupt  
INT3 Interrupt  
0bh  
2ch  
0ch  
0dh  
0eh  
0fh  
30h  
34h  
38h  
3ch  
f
10h  
40h  
10h  
11h  
INT4 Interrupt  
f
f
11h  
44h  
Asynchronous Serial Port 1 Interface  
Asynchronous Serial Port 0 Interface  
Reserved  
14h  
50h  
14h  
9
15h1fh  
54h7ch  
Note: If the priority levels are not changed, the default priority level will be used for the interrupt sources.  
a
Instruction execution generates interrupts.  
b
Performed in the same manner as for the 8086 and 8088.  
c
An ESC opcode causes a trap.  
d
Because only one IRQ is generated for the three timers, they share priority level with other sources. The  
timers have an interrupt priority order among themselves (2A > 2B > 2C).  
e
These interrupt types are programmable in slave mode.  
f
Not available in slave mode.  
4.18 Timer Control  
The IA186ES and IA188ES have a WDT and three 16-bit programmable timers. Timer0 and  
timer1 each has an input and output connected to external pins that permits it to count or time  
events as well as produce variable duty-cycle waveforms or non-repetitive waveforms. These  
same timers are used to measure the high- and low-pulse widths of the Pulse Width Demodulator  
on the pwd pin.  
Because timer2 does not have external connections, it is confined to internal functions such as  
real-time coding, time-delay applications, a prescaler for timer0 and timer1, or to synchronize  
DMA transfers.  
The Peripheral Control Block contains eleven 16-bit registers to control the programmable  
timers. Each timer-count register holds the present value of its associated timer and may be read  
from or written to whether the timer is in operation or not. The microcontroller increments the  
value of the timer-count register when a timer event takes place.  
®
IA211050902-19  
UNCONTROLLED WHEN PRINTED OR COPIED  
http://www.innovasic.com  
Customer Support:  
Page 55 of 154  