Data Sheet TLE 6225 G
Electrical Characteristics
Parameter and Conditions
Symbol
Values
Unit
VS = 4.5 to 32 V ; Tj = - 40 °C to + 150 °C
(unless otherwise specified)
min
typ
max
1. Power Supply
VS
V
Supply Voltage
4.5
32
Supply Current (ENA = H, Outputs ON)
Supply Current in Standby Mode (ENA = L)
IS(ON)
IS(stby)
1
2
10
mA
µA
2. Power Outputs
ON Resistance VS ≥ 6 V; ID = 300 mA
TJ = 25°C
TJ = 150°C
RDS(ON)
1.7
3
2
3.6
Ω
45
500
50
60
V
Output Clamping Voltage
Current Limit
Output OFF VDS(AZ)
750 1000 mA
ID(lim)
Output Leakage Current
VENA = L
5
10
10
µA
µs
µs
ID(lkg)
5
5
Turn-On Time
Turn-Off Time
ID = 200 mA, resistive load tON
ID = 200 mA, resistive load tOFF
3. Digital Inputs (IN1 – IN4, ENA, PRG)
Input Low Voltage (IN1 – IN4, PRG)
Input Low Voltage (ENA)
VINL
VINL
VINH
VINHys
VINHys
IIN(1..4)PU
- 0.3
- 0.3
2.0
50
20
20
1
0.8
V
V
V
mV
mV
µA
Input High Voltage
Input Voltage Hysteresis (IN1 – IN4, PRG)
Input Voltage Hysteresis (ENA)
Input Pull Up Current (IN1...IN4) @ PRG = L,
VIN = 0V
Input Pull Down Current (IN1...IN4) @ PRG = H,
VIN < VS; VIN < 6
100
100
50
100
100
IIN(1..4)PD
20
20
50
50
µA
PRG, ENA Pull Down Current
PRG, ENA Pull Down Current
VIN = 5 V
VIN = 14 V
IIN(PRG,ENA)
IIN(PRG,ENA)
100
200
µA
µA
4. Digital Output (FAULT )
FAULT Output Low Voltage
IFAULT = 1.6 mA
VFAULTL
0.4
V
5. Diagnostic Functions
Open Load/Short to Ground Detection Voltage
Output Pull Down Current
Fault Delay Time; VS = 12V
Overtemperature Shutdown Threshold
Hysteresis
VDS(OL)
IPD(OL)
td(fault)
Tth(sd)
Thys
0.4*VS 0.5*VS 0.6*VS
V
µA
µs
°C
K
20
50
50
100
200
200
200
170
10
V2.1
Page
26.Aug. 2002
4