欢迎访问ic37.com |
会员登录 免费注册
发布采购

PEB2091NV5.3 参数 Datasheet PDF下载

PEB2091NV5.3图片预览
型号: PEB2091NV5.3
PDF下载: 下载PDF文件 查看货源
内容描述: 集成电路通信( ISDN Echocancellation电路) [ICs for Communications(ISDN Echocancellation Circuit)]
分类和应用: 电信集成电路综合业务数字网通信
文件页数/大小: 299 页 / 1531 K
品牌: INFINEON [ Infineon ]
 浏览型号PEB2091NV5.3的Datasheet PDF文件第108页浏览型号PEB2091NV5.3的Datasheet PDF文件第109页浏览型号PEB2091NV5.3的Datasheet PDF文件第110页浏览型号PEB2091NV5.3的Datasheet PDF文件第111页浏览型号PEB2091NV5.3的Datasheet PDF文件第113页浏览型号PEB2091NV5.3的Datasheet PDF文件第114页浏览型号PEB2091NV5.3的Datasheet PDF文件第115页浏览型号PEB2091NV5.3的Datasheet PDF文件第116页  
PEB 2091  
PEF 2091  
Operational Description  
MON-0-commands may be passed at any instant and need to be transferred only once  
(applicable for Auto and Transparent mode). Code repetition is performed within the chip  
by the EOC processor.  
A summery of the EOC procedure in EOC Auto and Transparent modes is given in  
Figure 50, page 114. If the microprocessor mode is used, the IOM®-2 interface in Figure  
50 can be replaced by the µP interface.  
EOC Access in LT-Auto Mode  
In LT-Auto mode the "return message" reception is enabled after an EOC-command has  
been transmitted downstream. The activation of this function causes the LT IEC-Q to  
watch the EOC of the U-interface and to issue a MON-0-message after an identical  
EOC-message has been received during three consecutive frames. Thus in LT-Auto  
mode an acknowledgment of the MON-0-command is even possible if the new message  
is not different from the previous one.  
If no MON-0-command has been transmitted downstream, a MON-0-message is issued  
only after the "triple-last-look" criterion is fulfilled and if this message is different from the  
one previously accepted. New messages will be passed upstream independently of the  
address used, i.e. not only messages addressed with (000) or (111) but all received  
EOC-messages will be transmitted with MON-0-messages.  
LT-Transparent Mode  
In LT-transparent mode every 6 ms a MON-0-message containing the last received  
EOC-message is issued. This occurs even if no change occurred in the EOC-channel.  
No "triple-last-look" is performed before a MON-0-message is sent.  
NT-EOC-Auto Mode  
The seven defined EOC-commands listed in Table 19 will be executed automatically by  
the IEC-Q if they were sent with the address (000) or (111) and the d/m bit was set to  
message (1). Every new EOC-command will be acknowledged immediately, i.e. no  
triple-last-look (e.g. acknowledgment of LB1 command reads 01H, 51H) before the  
acknowledgment is transmitted.  
Table 19  
Predefined EOC Messages  
Code  
Hex.  
Symbol  
Function  
00  
50  
51  
52  
H
Hold  
LBBD  
LB1  
Close complete loop  
Close loop B1  
Close loop B2  
LB2  
Semiconductor Group  
112  
Data Sheet 01.99  
 
 复制成功!