Low Level Controller  
6.5  
LLC Routine Reference  
6.5.1  
ISAC®-S Layer-1 Functions: The SBC Part  
ActL1_SBC ()  
Initiates layer-1 activation. The appropriate CI code (activate request) is written to the CI  
channel if the layer 1 is not already activated. ActL1_SBC then returns with ACK_DONE. The  
subsequent status changes of the SBC will cause CI channel status change (CISQ) interrupts  
and these will be evaluated in the layer-1 interrupt service routine IntL1_SBC.  
If the layer 1 is already activated nothing is carried out but ActL1_SBC calls  
DECODE_L1_STATUS to report the activated state.  
DeaL1_SBC ()  
Initiates layer 1 deactivation. The appropriate CI code is written to the CI channel if the layer 1  
is not already deactivated. The subsequent layer 1 status changes cause CI channel status  
change (CISQ) interrupts and these will be evaluated in the layer 1 interrupt service routine  
IntL1_SBC.  
If the layer 1 is already deactivated nothing is carried out but DeaL1_SBC calls  
DECODE_L1_STATUS to report the deactivated state.  
ArL1_SBC ()  
Activates a local loop in the SBC. The appropriate CI code (activate request loop) is written to  
the SBC. ArL1_SBC returns with ACK_DONE. The subsequent status changes of the SBC will  
generate CISQ interrupts and these will be evaluated and reported in the layer-1 interrupt  
service routine IntL1_SBC.  
EnaClk_SBC ()  
EnaClk_SBC enables clocking in TE configurations when the layer 1 is in power down state.  
If first tests if clocks are actually there. If there are clocks the function returns with FALSE. If  
there are no clocks (power down state) the power-up procedure is implemented. The SPU bit  
in register SPCR is set. The TIM code is written to the CI channel. EnaClk_SBC waits until the  
power up state (PU) is indicated before the SPU bit is reset to 0. The routine then returns with  
TRUE.  
InitL1_SBC ()  
Initializes and resets the layer-1 controller (ResL1_SBC). Timing mode 0 is set and the TIC  
bus address is also programmed.  