IKFW60N60DH3E
TRENCHSTOPTMꢀAdvancedꢀIsolation
PG-TO247-3-AI (PGHSIP2473)
MILLIMETERS
DIMENSIONS
MIN.
MAX.
DOCUMENT NO.
A
A1
A2
A3
b
-
5.18
Z8B00186434
4.70
2.23
0.20
1.10
0.50
22.20
16.96
15.70
13.68
4.90
2.59
REVISION
0.28
02
1.30
SCALE 3:1
c
0.70
D
22.40
17.16
15.90
13.88
0 1
2 3 4 5 6 7 8mm
D1
E
EUROPEAN PROJECTION
E1
e
5.44
L
18.31
2.76
3.50
5.70
5.96
18.91
2.96
3.70
5.90
6.36
L1
øP
øP1
Q
ISSUE DATE
05.06.2018
Note:
For a proper handling and assembly of the advanced isolation device in the application the isolation layer must not be exposed to potential
penetration via sharp implements or mechanical impacts/shocks, which exceed levels indicated in International Standard (IEC6006826 and
IEC60068227). The advanced isolation device is intended only to be used assembled on an appropriate heatsink with recommended flatness
of <20µm per 100mm and roughness of <10µm.
Datasheet
13
Vꢀ2.1
2017-09-21