BTS 723 GW
Maximum Ratings at Tj = 25°C unless otherwise specified
Parameter
Symbol
Values
Unit
Supply voltage (overvoltage protection see page 6)
Vbb
Vbb
58
50
V
Supply voltage for full short circuit protection
Tj,start =-40 ...+150°C
V
Output Voltage to Vbb
VON
70
V
Negative voltage slope at output
-dVOUT/dt
IL
20 V/µs
1)
Load current (Short-circuit current, see page 7)
IL(LIM)
A
V
4)
Load dump protection2) VLoadDump = VA + Vs, VA = 27 V
RI3) = 8 Ω, td = 200 ms; IN= low or high,
each channel loaded with RL = 20 Ω,
VLoaddump
70
Operating temperature range
Storage temperature range
Power dissipation (DC)5)
(all channels active)
Tj
-40 ...+150
-55 ...+150
°C
W
Tstg
Ta = 25°C: Ptot
Ta = 85°C:
3.0
1.6
Maximal switchable inductance, single pulse
Vbb =12V, Tj,start =150°C5),
23.0
30.0
mH
kV
I = 2.5 A, EAS = 110 mJ, 0Ω
one channel: ZL
two parallel channels:
IL = 3.5 A, EAS = 278 mJ, 0Ω
L
see diagrams on page 12
Electrostatic discharge capability (ESD):
(Human Body Model) acc. MIL-STD883D, method 3015.7 and ESD
VESD
1.0
assn. std. S5.1-1993 R=1.5kΩ; C=100pF
Input voltage (DC)
VIN
IIN
IST
±42
±2.0
±2.0
±42
V
Current through input pin (DC)
Current through status pin (DC)
Status pull up voltage
mA
VSPU
V
1
)
Current limit is a protection function. Operation in current limitation is considered as "outside" normal
operating range. Protection functions are not designed for continuous repetitive operation.
Supply voltages higher than Vbb(AZ) require an external current limit for the GND and status pins (a 150Ω
2)
resistor for the GND connection is recommended.
3)
4)
5)
R = internal resistance of the load dump test pulse generator
I
VLoad dump is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839
Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm2 (one layer, 70µm thick) copper area for V
bb
connection. PCB is vertical without blown air. See page 15
Infineon Technologies AG
4