BTS7040-1EPA
PROFET™ +2 12V
Protection
IL(OVL0) variation over TJ
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
reference value
"1" = IL(OVL0) typ @ -40 °C
Typ
0.0
-40
-20
0
20
40
60
80
100
120
140
160
Junction Temperature (°C)
Figure 25 Overload Current Thresholds variation with TJ
Power supply voltage VS can increase above 18 V for short time, for instance in Load Dump or in Jump Start
condition. Whenever VS ≥ VS(JS), the overload detection current is set to IL(OVL_JS) as shown in Figure 26.
IL(OVL)
IL(OVL0)
IL(OVL_JS)
VS
VS(JS),min VS(JS),max
Protection_JS.emf
Figure 26 Overload Detection Current variation with VS voltage
When IL ≥ IL(OVL) (either IL(OVL0), IL(OVL1) or IL(OVL_JS)), the channel is switched OFF. The channel is allowed to restart
according to the retry strategy described in Chapter 8.3.
Data Sheet
33
Rev. 1.10
2020-12-14