BTS7040-1EPA
PROFET™ +2 12V
Power Stages
Table 12 Electrical Characteristics: Power Stages - PROFET™ (continued)
Parameter
Symbol
Values
Typ.
Unit Note or
Test Condition
Number
Min.
Max.
Voltage Slope
Switch-ON Slew Rate
(dV/dt)ON
0.3
0.6
0.9
V/μs VS = 13.5 V
P_7.4.1.6
VOUT = 30% to 70%
of VS
See Figure 16
Switch-OFF Slew Rate
-(dV/dt)OFF 0.3
0.6
0.9
V/μs VS = 13.5 V
P_7.4.1.7
VOUT = 70% to 30%
of VS
See Figure 16
Slew Rate Matching
(dV/dt)ON - (dV/dt)OFF
Δ(dV/dt)SW -0.15
0
7
0.15
18
V/μs VS = 13.5 V
P_7.4.1.8
P_7.4.1.9
Voltages
1)
Output Voltage Drop
Limitation at Small Load
Currents
VDS(SLC)
2
mV
DEN = “high”
IL = IL(OL) = 20 mA
See Figure 18
1) Not subject to production test - specified by design.
7.5
Electrical Characteristics - Power Output Stages
VS = 6 V to 18 V, TJ = -40 °C to +150 °C
Typical values: VS = 13.5 V, TJ = 25 °C
Typical resistive load connected to the output for testing (unless otherwise specified):
RL = 3.3 Ω
7.5.1
Power Output Stage - 40 mΩ
Table 13 Electrical Characteristics: Power Stages - 40 mΩ
Parameter
Symbol
Values
Typ.
Unit Note or
Test Condition
Number
Min.
Max.
Output characteristics
1)
ON-State Resistance at
TJ = 25 °C
RDS(ON)_25
RDS(ON)_150
–
–
–
19
–
–
mΩ
mΩ
mΩ
P_7.5.6.1
P_7.5.6.2
P_7.5.6.3
TJ = 25 °C
ON-State Resistance at
TJ = 150 °C
36
45
TJ = 150 °C
IL = 2 A
ON-State Resistance in
Cranking
RDS(ON)_CRAN
–
TJ = 150 °C
VS = 3.1 V
IL = 0.75 A
K
Data Sheet
27
Rev. 1.10
2020-12-14