BTS7012-2EPA
PROFET™ +2 12V
Diagnosis
9.6
Electrical Characteristics Diagnosis - Power Output Stages
VS = 6 V to 18 V, TJ = -40 °C to +150 °C
Typical values: VS = 13.5 V, TJ = 25 °C
Typical resistive loads connected to the outputs for testing (unless otherwise specified):
RL = 3.3 Ω
9.6.1
Diagnosis Power Output Stage - 12 mΩ
Table 22 Electrical Characteristics: Diagnosis - 12 mΩ
Parameter
Symbol
Values
Typ.
Unit Note or
Test Condition
Number
Min.
Max.
Open Load Output Current IL(OL)_4u
at IIS = 4 µA
6
18.5
32
mA
IIS = IIS(OL) = 4 µA
See Figure 34
P_9.7.3.1
P_9.7.3.6
P_9.7.3.9
P_9.7.3.12
P_9.7.3.15
P_9.7.3.17
P_9.7.3.19
P_9.7.3.21
P_9.7.3.27
Current Sense Ratio at
IL = IL02
kILIS02
kILIS05
kILIS08
kILIS11
kILIS13
kILIS15
kILIS17
ΔkILIS(OL)
-34.0% 4785
-25.0% 4785
-22.5% 4785
-12.5% 4785
-7.7% 4785
-4.5% 4785
-4.0% 4785
+34.0%
+25.0%
+22.5%
+12.5%
+7.7%
+4.5%
+4.0%
+30
IL02 = 20 mA
IL05 = 100 mA
IL08 = 250 mA
IL11 = 1 A
Current Sense Ratio at
IL = IL05
Current Sense Ratio at
IL = IL08
Current Sense Ratio at
IL = IL11
Current Sense Ratio at
IL = IL13
IL13 = 2 A
Current Sense Ratio at
IL = IL15
IL15 = 4 A
Current Sense Ratio at
IL = IL17
IL17 = 7 A
1)
SENSE Current Derating
with Low Current
Calibration
-30
0
%
%
IL(CAL)_OL = IL05
IL(CAL)_OL_H = IL08
IL(CAL)_OL_L = IL02
TA(CAL) = 25 °C
See Figure 33
1)
SENSE Current Derating
with Nominal Current
Calibration
ΔkILIS(NOM) -4
0
+4
P_9.7.3.29
IL(CAL) = IL15
IL(CAL)_H = IL17
IL(CAL)_L = IL13
TA(CAL) = 25 °C
See Figure 33
1) Not subject to production test - specified by design.
Data Sheet
53
Rev. 1.10
2020-12-14