Advance
Micropower Dual 150mA CMOS RF LDO™ Regulators with 75dB Ripple Rejection
Electrical Characteristics ILC7280CS
Unless otherwise specified, all limits are at TA = 25°C; VIN = VO(NOM) + 1V, IOUT = 1mA, COUT = 0.47µF, VS/D = 2V.
Boldface limits apply over the operating temperature range. (Note 2)
Parameter
Symbol
Conditions
Min
2.0
Typ
Max Units
10
VS/D
High = Regulator On
Low = Regulator Off
Shut Down Input Voltage
V
0.6
IO(peak)
eN
VOUT > 0.95VO(NOM)
500
Peak Output Current (Note 4)
300
mA
Output Noise Voltage (RMS)
µV
dB
BW = 300Hz to 50kHz, CNOISE = 0pF
60
60
freq = 1kHz
Ripple Rejection
∆VO/∆VIN
∆VO(line)
freq = 10kHz
freq = 100kHz
VIN: VO(NOM) + 1V to VO(NOM) + 2V; dVIN/dt
1V/µS;lo = 150mA
60
10
Dynamic Line Regulation
=
mV
40
20
IOUT: 0 to 150mA; d(lOUT)/dt = 50A/µs, with
COUT = 2.2µF
∆VO(load)
Dynamic Load Regulation
Short Circuit Current
mV
mA
ISC
VOUT = 0V
300
Note1: Absolute maximum ratings indicate limits which when exceeded may result in damage to the component. Electrical specifications do not apply
when operating the device outside of its rated operating conditions.
Note 2: Specified Min/Max limits are production tested or guaranteed through correlation based on statistical control methods. Measurements are
taken at constant junction temperature as close to ambient as possible using low duty pulse testing.
Note 3: Dropout Voltage is defined as the measured Differential Voltage between input and output voltage, when the output voltage drops 2% below the nominal output
voltage as VIN is decreased, and approaches VOUT . Nominal output voltage is defined at VIN = VOUT + 1V.
Note 4: Guaranteed by design
Impala Linear Corporation
ILC7280 1.8
www.impalalinear.com
(408) 574-3939
May 2000
5