欢迎访问ic37.com |
会员登录 免费注册
发布采购

502-DPK 参数 Datasheet PDF下载

502-DPK图片预览
型号: 502-DPK
PDF下载: 下载PDF文件 查看货源
内容描述: [Clock Generator, 190MHz, CMOS, DIE]
分类和应用: 时钟外围集成电路晶体
文件页数/大小: 7 页 / 176 K
品牌: IDT [ INTEGRATED DEVICE TECHNOLOGY ]
 浏览型号502-DPK的Datasheet PDF文件第1页浏览型号502-DPK的Datasheet PDF文件第2页浏览型号502-DPK的Datasheet PDF文件第4页浏览型号502-DPK的Datasheet PDF文件第5页浏览型号502-DPK的Datasheet PDF文件第6页浏览型号502-DPK的Datasheet PDF文件第7页  
ICS502
LOCO™ PLL CLOCK MULTIPLIER
CLOCK MULTIPLIER
External Components
Decoupling Capacitor
As with any high-performance mixed-signal IC, the ICS502
must be isolated from system power supply noise to perform
optimally.
A decoupling capacitor of 0.01µF must be connected
between VDD and GND. It must be connected close to the
ICS502 to minimize lead inductance. No external power
supply filtering is required for the ICS502.
Crystal Load Capacitors
The device crystal connections should include pads for
small capacitors from X1 to ground and from X2 to ground.
These capacitors are used to adjust the stray capacitance of
the board to match the nominally required crystal load
capacitance. Because load capacitance can only be
increased in this trimming process, it is important to keep
stray capacitance to a minimum by using very short PCB
traces (and no vias) between the crystal and device. Crystal
capacitors, if needed, must be connected from each of the
pins X1 and X2 to ground.
The value (in pF) of these crystal caps should equal (C
L
-12
pF)*2. In this equation, C
L
= crystal load capacitance in pF.
Example: For a crystal with a 16 pF load capacitance, each
crystal capacitor would be 8 pF [(16-12) x 2] = 8.
Series Termination Resistor
A 33
terminating resistor can be used next to the CLK pin.
The total on-chip capacitance is approximately 12 pF. A
parallel resonant, fundamental mode crystal should be
used.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS502. These ratings, which are
standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these
or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Item
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature (industrial)
Ambient Operating Temperature (commercial)
Storage Temperature
Soldering Temperature
7V
Rating
-0.5 V to VDD+0.5 V
-40 to +85
°
C
0 to +70
°
C
-65 to +150
°
C
260
°
C
Recommended Operation Conditions
Parameter
Ambient Operating Temperature (commercial)
Ambient Operating Temperature (industrial)
Power Supply Voltage (measured in respect to GND)
Min.
0
-40
+3
Typ.
Max.
+70
+85
+5.5
Units
°
C
°
C
V
IDT™ / ICS™
LOCO™ PLL CLOCK MULTIPLIER
3
ICS502
REV M 051310