REAL-TIME CLOCK WITH SERIAL I2C INTERFACE  
RTC  
The user determines diode and resistor selection according to the maximum current desired for battery or super cap  
charging. The maximum charging current can be calculated as illustrated in the following example. Assume that a 3.3 V  
system power supply is applied to VCC and a super cap is connected to VBACKUP. Also assume that the trickle charger has  
been enabled with a diode and resistor R2 between VCC and VBACKUP. The maximum current IMAX would therefore be  
calculated as follows:  
IMAX = (3.3 V - diode drop) / R2 (3.3 V - 0.7 V) / 2k1.3 mA  
As the super cap or battery charges, the voltage drop between VCC and VBACKUP decreases and therefore the charge  
current decreases.  
2
I C Serial Data Bus  
The IDT1339 supports the I2C bus protocol. A device that  
sends data onto the bus is defined as a transmitter and a  
device receiving data as a receiver. The device that controls  
the message is called a master. The devices that are  
controlled by the master are referred to as slaves. The bus  
must be controlled by a master device that generates the  
serial clock (SCL), controls the bus access, and generates  
the START and STOP conditions. The IDT1339 operates as  
a slave on the I2C bus. Within the bus specifications, a  
standard mode (100 kHz cycle rate) and a fast mode (400  
kHz cycle rate) are defined. The IDT1339 works in both  
modes. Connections to the bus are made via the open-drain  
I/O lines SDA and SCL.  
the line must be changed during the LOW period of the clock  
signal. There is one clock pulse per bit of data.  
Each data transfer is initiated with a START condition and  
terminated with a STOP condition. The number of data  
bytes transferred between START and STOP conditions is  
not limited, and is determined by the master device. The  
information is transferred byte-wise and each receiver  
acknowledges with a ninth bit.  
Acknowledge: Each receiving device, when addressed, is  
obliged to generate an acknowledge after the reception of  
each byte. The master device must generate an extra clock  
pulse that is associated with this acknowledge bit.  
The following bus protocol has been defined (see the “Data  
Transfer on I2C Serial Bus” figure):  
A device that acknowledges must pull down the SDA line  
during the acknowledge clock pulse in such a way that the  
SDA line is stable LOW during the HIGH period of the  
acknowledge related clock pulse. Of course, setup and hold  
times must be taken into account. A master must signal an  
end of data to the slave by not generating an acknowledge  
bit on the last byte that has been clocked out of the slave. In  
this case, the slave must leave the data line HIGH to enable  
the master to generate the STOP condition.  
Data transfer may be initiated only when the bus is not  
busy.  
During data transfer, the data line must remain stable  
whenever the clock line is HIGH. Changes in the data line  
while the clock line is HIGH are interpreted as control  
signals.  
Accordingly, the following bus conditions have been defined:  
Timeout: Timeout is where a slave device resets its  
interface whenever Clock goes low for longer than the  
timeout, which is typically 35mSec. This added logic deals  
with slave errors and recovering from those errors. When  
timeout occurs, the slave interface should re-initialize itself  
and be ready to receive a communication from the master,  
but it will expect a Start prior to any new communication.  
Bus not busy: Both data and clock lines remain HIGH.  
Start data transfer: A change in the state of the data line,  
from HIGH to LOW, while the clock is HIGH, defines a  
START condition.  
Stop data transfer: A change in the state of the data line,  
from LOW to HIGH, while the clock line is HIGH, defines the  
STOP condition.  
Data valid: The state of the data line represents valid data  
when, after a START condition, the data line is stable for the  
duration of the HIGH period of the clock signal. The data on  
IDT® REAL-TIME CLOCK WITH SERIAL I2C INTERFACE  
11  
IDT1339  
REV K 032910