ICS1893CF Data Sheet - Release
Chapter 7 Management Register Set
7.12 Register 17: Quick Poll Detailed Status Register
Table 7-18 lists the bits for the Quick-Poll Detailed Status Register. This register is a 16-bit read-only
register used to provide an STA with detailed status of the ICS1893CF operations. During reset, it is
initialized to pre-defined default values.
Note:
1. For an explanation of acronyms used in Table 7-18, see Chapter 1, “Abbreviations and Acronyms”.
2. Most of this register’s bits are latching high or latching low, which allows the ICS1893CF to capture and
save the occurrence of an event for an STA to read. (For more information on latching high and latching
low bits, see Section 7.1.4.1, “Latching High Bits” and Section 7.1.4.2, “Latching Low Bits”.)
3. Although some of these status bits are redundant with other management registers, the ICS1893CF
provides this group of bits to minimize the number of Serial Management Cycles required to collect the
status data.
Table 7-18. Quick Poll Detailed Status Register (register 17 [0x11])
Bit
Definition
When Bit = 0
When Bit = 1
Ac-
cess
SF
De- Hex
fault
17.15 Data rate
17.14 Duplex
10 Mbps
Half duplex
100 Mbps
Full duplex
RO
RO
RO
–
–
–
–
0
–
17.13 Auto-Negotiation
Progress Monitor Bit 2
Reference Decode Table Reference Decode Table
Reference Decode Table Reference Decode Table
Reference Decode Table Reference Decode Table
LMX
17.12 Auto-Negotiation
Progress Monitor Bit 1
RO
RO
RO
RO
LMX
LMX
LH
0
0
0
0
17.11 Auto-Negotiation
Progress Monitor Bit 0
0
17.10 100Base-TX signal
lost
Valid signal
PLL locked
Signal lost
17.9
100BasePLL Lock
Error
PLL failed to lock
LH
17.8
17.7
False Carrier detect
Normal Carrier or Idle
Valid symbols observed
False Carrier
RO
RO
LH
LH
0
0
Invalid symbol
detected
Invalid symbol received
0
17.6
17.5
Halt Symbol detected No Halt Symbol received Halt Symbol received
RO
RO
LH
LH
0
0
Premature End
detected
Normal data stream
Stream contained two
IDLE symbols
17.4
17.3
Auto-Negotiation
complete
Auto-Negotiation in
process
Auto-Negotiation
complete
RO
RO
–
–
0
0
100Base-TX signal
detect
Signal present
No signal present
0
17.2
17.1
17.0
Jabber detect
Remote fault
Link Status
No jabber detected
Jabber detected
RO
RO
RO
LH
LH
LL
0
0
0
No remote fault detected Remote fault detected
Link is not valid Link is valid
ICS1893CF, Rev. F, 03/01/07
Mar. 2007
Copyright © 2007, Integrated Device Technology, Inc.
All rights reserved.
72