X24C04
ABSOLUTE MAXIMUM RATINGS*
.................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
Temperature Under Bias
Voltage on any Pin with
............................ –1.0V to +7.0V
Respect to V
SS
D.C. Output Current ............................................ 5 mA
This is a stress rating only and the functional operation of the
device at these or any other conditions above those
indicated in the operational sections of this specification is not
implied. Exposure to absolute maximum rating condition
Lead Temperature (Soldering,
............................. 300°C
RECOMMENDED OPERATING CONDITIONS
10 Seconds)
for extended periods may affect device reliability.
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
Industrial
Military
0°C
70°C
+85°C
+125°C
X24C04
4.5V to 5.5V
3.5V to 5.5V
3V to 5.5V
–40°C
–55°C
X24C04-3.5
X24C04-3
X24C04-2.7
3836 PGM T02
2.7V to 5.5V
3836 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Limits
Symbol
Parameter
Min.
Max.
Units
Test Conditions
SCL = VCC x 0.1/VCC x 0.9 Levels
I
V
V
Supply Current (Read)
Supply Current (Write)
1
3
CC1
CC
I
mA @ 100 KHz, SDA = Open, All Other
Inputs = GND or VCC – 0.3V
CC2
CC
(1)
∝A
SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 5.5V
SCL = SDA = VCC – 0.3V, All Other
V
V
Standby Current
Standby Current
ISB1
150
50
CC
(1)
∝A
ISB2
CC
Inputs = GND or VCC
,
V
CC
= 3V
∝A
∝A
I
V
= GND to V
CC
Input Leakage Current
Output Leakage Current
Input Low Voltage
10
10
LI
IN
I
LO
VOUT = GND to VCC
(2)
V
x 0.3
VlL
–1.0
V
V
V
CC
(2)
V
x 0.7V + 0.5
CC
VIH
Input High Voltage
CC
V
I
OL
= 3 mA
Output Low Voltage
0.4
OL
3839 PGM T03
CAPACITANCE TA = 25°C, f = 1.0MHz, VCC = 5V
Symbol
Parameter
Max.
Units
Test Conditions
(3)
V
V
= 0V
CI/O
Input/Output Capacitance (SDA)
8
6
pF
pF
I/O
(3)
Input Capacitance (A , A , A , SCL)
2
= 0V
CIN
0
1
IN
3839 PGM T05
Notes:(1)Must perform a stop command prior to measurement.
(2)VIL min. and VIH max. are for reference only and are not tested.
(3)This parameter is periodically sampled and not 100% tested.
9