iC-TW8 16-BIT SIN/COS INTERPOLATOR  
Serial Configuration Mode  
Jan 9, 2013 Page SC35/36  
1 Input Cycle  
the unused harmonic. The design tool shows the re-  
sultant angular error due to the distortion and the  
residual error left after correction. The residual an-  
gular error is due to the finite (8 bit) resolution of  
the LUT.  
SIN  
COS  
For example, if FFT analysis of a particular sensor  
showed 2% second harmonic distortion at 0° phase  
shift and 1% third order harmonic distortion at 180°  
phase shift, the following angular error results.  
360°  
Sensor  
Input  
Angle  
LUT  
Output  
Angle  
0°  
127  
LUT  
0
Values  
–127  
Figure 39: Constant LUT  
A constant LUT is useful in single turn absolute ap-  
plications such as synchronous AC motor commuta-  
tion where the feedback signal must be aligned to  
the motor poles. For example, to shift the interpola-  
tor 0° position 3.8° to the right, the constant LUT  
value is calculated as  
Figure 40: Sensor Distortion  
3.8 16384  
The design tool shows that this sensor distortion  
produces peak angular error of 1.88 input cycle de-  
grees. After correction by the LUT, 0.04° (15.76 arc  
minutes) of angular error remain.  
 43  
360  
4
More complex LUTs require careful FFT measure-  
ment of sensor distortion. When sensor distortion  
harmonics are known, the design tool can be used to  
calculate a LUT that corrects for up to two sensor  
harmonics which are identical on both Sin and Cos  
input channels.  
The GUI LUT tab in the design tool shown the cal-  
culated LUT as a graph and LUT values. Save the  
GUI LUT tab as a .csv file for direct import into the  
GUI software. The LUT entries are also copied into  
the GUI Hex tab of the design tool.  
In the LUT Configuration tab of the design tool,  
enter up to two sensor distortion harmonic to be cor-  
rected. The harmonic number, amplitude in percent,  
and phase in degrees are required. To correct for  
only one distortion harmonic enter 0 amplitude for  
Copyright © 2011–2013 iC-Haus  
http://www.ichaus.com  