iC-TW8 16-BIT SIN/COS INTERPOLATOR  
Serial Configuration Mode  
Jan 9, 2013 Page SC9/36  
These conditions can be monitored in real time over  
either of the serial ports by reading the STAT_EE  
register in the VAR block in internal memory.  
Auto Store  
The iC-TW8’s Auto Store feature automatically  
stores adapted parameter values to the EEPROM  
during operation for use as the startup values at the  
next power-up. A double buffer is used which en-  
sures a consistent set of AB signal path parameters  
at every startup. Auto store is controlled by varia-  
bles in the ADPT_STORE register in the CFG block  
of internal memory.  
The conditions that activate or latch the FAULT  
output are determined by bits in the FLT_CFG and  
FLT_EN registers in the CFG block in internal  
memory.  
ADC and Adaption Quality Monitors  
The iC-TW8 provides a sophisticated quality evalu-  
ation feature with a hardware STATUS output (pin  
19) to monitor signal amplitude and auto adaption  
during operation. Operation of the quality monitors  
is controlled by bits in the MON_CFG register in  
the CFG block in internal memory. Real-time quali-  
ty status is also available over the serial ports.  
Fault Handling  
The iC-TW8 provides comprehensive fault handling  
features and a hardware FAULT output (pin 20) to  
notify external systems of faults and warnings dur-  
ing operation. Real-time fault status is also available  
over the serial ports.  
The following signal path conditions are monitored  
and can be configured to activate the FAULT out-  
put.  
The ADC Quality Monitor continuously evaluates  
the amplitude of the sensor signal at the output of  
the analog-to-digital converters in the AB signal  
path and provides a pulse-width modulated signal  
on the STATUS output that is inversely proportional  
to relative signal amplitude. Thus the STATUS out-  
put can be used to drive an LED whose brightness  
or color is proportional to sensor signal amplitude  
for early warning of a possible future failure. The  
ADC quality monitor levels are determined by vari-  
ables in the MON_ADC register in the CFG block  
in internal memory.  
Signal Path Fault/Status  
Conditions  
ADC overflow  
ADC underflow  
Excessive adaption  
Speed limit exceeded  
Overspeed warning  
Fatal overspeed fault  
Excessive filter lag  
Excessive AB output lag  
1-wire interface time-out  
External crystal fault  
The Adaption Quality Monitor continuously evalu-  
ates the deviation of the adapted AB signal path pa-  
rameters from their base values and provides a  
pulse-width modulated signal on the STATUS out-  
put that is proportional to the amount of deviation.  
Thus the STATUS output can be used to drive an  
LED whose brightness or color is proportional to  
the relative amount of adaption that has occurred for  
early warning of a possible future failure. The adap-  
tion quality monitor levels are determined by varia-  
bles in the MON_OFF, MON_GAIN, and  
MON_PHASE registers in the CFG block in inter-  
nal memory.  
These conditions can be monitored in real time over  
either of the serial ports by reading the STAT_SP  
register in the VAR block in internal memory.  
The following EEPROM conditions are monitored  
and can be configured to activate the FAULT out-  
put.  
EEPROM Fault/Status  
Conditions  
Communication timeout  
Hardware fault  
Wrong EEPROM ID  
CFG block checksum error  
PAR Block 0 checksum error  
PAR Block 1 checksum error  
PAR_BASE block checksum error  
LUT block checksum error  
Wrong configuration mode  