iC-NQC
13-bit Sin/D CONVERTER WITH SIGNAL CALIBRATION
Rev B1, Page 21/29
Regardless of register protection settings a short time- The value written to address 0x7C is also transferred
out of typically 1.8 µs can be temporarily activated by to the EEPROM, provided an EEPROM has been con-
writing value 0x07 to address 0x7C (address 124d). nected up and is available.
A controller can then transmit the device configuration
over a shorter period.
On reading address 0x7C the byte stored in the EEP-
ROM is output as part of the BiSS device ID. Here,
high-order bits 7:3 are part of the manufacturer’s ID;
low-order bits 2:0 act as an indicator of the timeout op-
tions (regular or short timeout, see Table 43).
TOS
Adr 0x7C, Bit 2:0
Code
000
Function
Regular timeout (configured by TIMO)
Short timeout (equal to TIMO = 1)
001...111
Table 43: Short timeout (via BiSS device ID)