欢迎访问ic37.com |
会员登录 免费注册
发布采购

IC-MQEVALMQ1D 参数 Datasheet PDF下载

IC-MQEVALMQ1D图片预览
型号: IC-MQEVALMQ1D
PDF下载: 下载PDF文件 查看货源
内容描述: 可编程的9位正弦/余弦插值用IC RS422驱动器 [PROGRAMMABLE 9-BIT Sin/Cos INTERPOLATION IC WITH RS422 DRIVER]
分类和应用: 驱动器
文件页数/大小: 39 页 / 816 K
品牌: ICHAUS [ IC-HAUS GMBH ]
 浏览型号IC-MQEVALMQ1D的Datasheet PDF文件第19页浏览型号IC-MQEVALMQ1D的Datasheet PDF文件第20页浏览型号IC-MQEVALMQ1D的Datasheet PDF文件第21页浏览型号IC-MQEVALMQ1D的Datasheet PDF文件第22页浏览型号IC-MQEVALMQ1D的Datasheet PDF文件第24页浏览型号IC-MQEVALMQ1D的Datasheet PDF文件第25页浏览型号IC-MQEVALMQ1D的Datasheet PDF文件第26页浏览型号IC-MQEVALMQ1D的Datasheet PDF文件第27页  
iC-MQ PROGRAMMABLE 9-BIT  
Sin/Cos INTERPOLATION IC WITH RS422 DRIVER  
Rev D4, Page 23/39  
Signal Conditioning Examples  
1. Photodiode array connected to current inputs, LED supply with constant current source  
Step  
1.  
Operating Mode  
Calibration and Signal  
Presets  
VOS12= 0x3, GF1= 0x40, VDC1= 0x20, OF1= 0x0, GF2= 0x10, VDC2= 0x20, OF2= 0x0  
Example: LED current approx. 6.25 mA  
ADJ(8)= 1 (constant current source), ADJ(6:5)= 11 (range 50 mA), ADJ(4:0)= 0x04 (value 12.5)  
2.  
Calibration 2  
Calibration of Channel 1:  
Parameter GR12: Adjust diff. signal at PA vs. NA to approx. 1 Vpp amplitude  
Parameter GF1: Adjust diff. signal at PA vs. NA to exactly 1 Vpp amplitude  
Parameter VDC1: Minimization of VDC1 AC fraction at output PZ (ripple < 10 mVpeak)  
Parameter OR1, OF1: Calibration of DC fraction to zero for diff. signal PA vs. NA (< 5 mVdc)  
3.  
4.  
Calibration 2  
System Test  
Calibration of Channel 2:  
Parameter GF2: Adjust diff. signal at PB vs. NB to exactly 1 Vpp amplitude  
Parameter VDC2: Minimization of VDC2 AC fraction at ouput NZ (ripple < 10 mVpeak)  
Parameter OR2, OF2: Calibration of DC fraction to zero for diff. signal PB vs. NB (< 5 mVdc)  
1. Iteration, Calibration of Channel 1 vs. Channel 2:  
Parameter OF1: Adjust duty ratio of A4 at PA to 50 %  
Parameter OF2: Adjust duty ratio of B4 at PB to 50 %  
Parameter PH12: Adjust duty ratio of A8 at NA to 50 %  
Parameter GF1: Adjust duty ratio of B8 at NB to 50 %  
5.  
6.  
Calibration 2  
System Test  
Repeated Adjustment of Intermediate Voltages, VDC1 and VDC2:  
Parameter VDC1: Minimization of VDC1 AC fraction at ouput PZ  
Parameter VDC2: Minimization of VDC2 AC fraction at ouput NZ  
2. Iteration, Calibration of Channel 1 vs. Channel 2:  
Parameter OF1: Adjust duty ratio of A4 at PA to 50 %  
Parameter OF2: Adjust duty ratio of B4 at PB to 50 %  
Parameter PH12: Adjust duty ratio of A8 at NA to 50 %  
Parameter GF1: Adjust duty ratio of B8 at NB to 50 %  
Table 31: Conditioning example 1  
2. Encoder supplying 100 mVpp to voltage inputs  
Step  
1.  
Operating Mode  
Calibration and Signal  
Presets  
VOS12= 0x1, GF1= 0x40, OF1= 0x0, GF2= 0x10, OF2= 0x0  
2.  
Calibration 2  
Calibration of Channel 1:  
Parameter GR12: Adjust diff. signal at PA vs. NA to approx. 1 Vpp amplitude  
Parameter GF1: Adjust diff. signal at PA vs. NA to exactly 1 Vpp amplitude  
Parameter OR1, OF1: Calibration of DC fraction to zero for diff. signal PA vs. NA (< 5 mVdc)  
3.  
4.  
Calibration 2  
System Test  
Calibration of Channel 2:  
Parameter GF2: Adjust diff. signal at PB vs. NB to exactly 1 Vpp amplitude  
Parameter OR2, OF2: Calibration of DC fraction to zero for diff. signal PB vs. NB (< 5 mVdc)  
Calibration of Channel 1 vs. Channel 2:  
Parameter OF1: Adjust duty ratio of A4 at PA to 50 %  
Parameter OF2: Adjust duty ratio of B4 at PB to 50 %  
Parameter PH12: Adjust duty ratio of A8 at NA to 50 %  
Parameter GF1: Adjust duty ratio of B8 at NB to 50 %  
Table 32: Conditioning example 2