iC-MH  
12 BIT ANGULAR HALL ENCODER  
Rev B1, Page 20/23  
mode it is not possible to vary the parameter set. The justified and filled with preceding zeros if necessary.  
data is transmitted as reduced Gray code, e.g. after The following table shows the data length according to  
converting into binary code, the data range is symmet- the resolution.  
rical to the center of the number string. For example,  
with a set resolution of 360 data values between 76  
and 435 are transmitted.  
DLEN  
Adr 0x43; Bit 3:0  
2
CFGRES = ’00000000’, 4  
3
CFGRES = ’00000001’, 8  
4
CFGRES = ’0000001x’, 12 to 16  
CFGRES = ’000001xx’, 20 to 32  
CFGRES = ’00001xxx’, 36 to 64  
CFGRES = ’0001xxxx’, 68 to 128  
CFGRES = ’001xxxxx’, 132 to 256  
CFGRES = ’01xxxxxx’, 260 to 512  
CFGRES = ’10000000’, 1024  
CFGRES = ’10000001’, 2048  
CFGRES = ’10000010’, 4096  
5
6
7
8
9
10  
11  
12  
Figure 24: SSI protocol, data GRAY-coded  
The register range 0x00 to 0x0F is equivalent to the  
settings with which the IC can be parameterized. The  
settings directly affect the corresponding switching  
parts. It is important to note that test register 0x0E can  
only be written to when pin VZAP is connected to VPD.  
When VPD > 6 V, write access to the test register is ig-  
nored. Register 0x0F can be configured at potentials  
V(VZAP) > Vt(VZAP)hi.  
Table 30: Data length  
The status register provides information on the status  
of the module. There are 5 different errors that can  
be signaled. Following unsuccessful programming of  
the zapping diodes, the bit PROGERR is set. If an  
attempt is made to read the current position via the se-  
rial interface during the start-up phase, an error is sig-  
naled with ERRSDATA, as the actual position is not yet  
known. The ERRAMAX bit is output to signal that the  
amplitude is too high, while the ERRAMIN bit signals  
an amplitude which is too low, caused, for example, by  
too great a distance to the magnet. If the NERR pin  
is pulled against VND outside the module, this error is  
also signaled via the serial interface. The ERREXT bit  
is then equal to ’1’. The error bits are reset again after  
the status register is read out at the address 0x77. The  
error bit in the data word is then also read in the next  
cycle as ’0’.  
The range 0x10 to 0x1F is read-only and reflects the  
contents of the integrated zapping diodes. Following  
programming the data can be verified via these ad-  
dresses. After the supply voltage is connected, the  
contents of the zapping diodes are copied to the RAM  
area 0x00 to 0x0F. Then the settings can be overwrit-  
ten via the serial interface. Overwriting is not possible  
if the CFGPROT bit is set.  
Errors in the module are signaled via the error mes-  
sage output NERR. This open-drain output signals an  
error if the output is pulled against VND. If the er-  
ror condition no longer exists, then the pin is released  
again after a waiting time of approximately 1 ms. If the  
integrated pull-up resistor is deactivated with DPU =  
’1’, then an external resistor must be provided. With  
DPU = ’0’ it brings the pin up to the high level again.  
CFGTOS  
CFGTOB  
Timeout  
16 µs  
2 µs  
0
1
x
0
0
1
2 µs  
Table 31: Timeout for sensor data  
DPU  
Adr 0x04; Bit 6  
Pull-up activated  
0
1
Pull-up deactive  
The timeout can be programmed to a shorter value  
with the CFGTOS bit. However, this setting is reset  
to the default value 16 µs again following a reset. The  
timeout can be permanently programmed for faster  
data transmission with the CFGTOB register via a zap-  
ping diode. Resetting to slower data transmission is  
then not possible.  
Table 29: Activation of NERR pull-up  
With the profile ID, the data format can be requested  
for the following sensor data cycles in the module. A  
read operation at address 0x42 results in 0x2C, with is  
the equivalent to 12-bit single-cycle data. The register  
0x43 which follows now contain the data length DLEN The registers 0x7D to 0x7F are reserved for the man-  
of the transmitted sensor data in accordance with the ufacturer and can be provided with an ID so that the  
set resolution. The sensor data are transmitted right- manufacturer can identify its modules  