iC-MH  
12 BIT ANGULAR HALL ENCODER  
Rev B1, Page 15/23  
CALIBRATION USING INCREMENTAL SIGNALS  
distance of the rising edge (equivalent to angle posi-  
If test mode cannot be used, signals can also be cali- tions of 0° and 180°) at signal A should be exactly half  
brated using the incremental signals or the values read a period (PER). Should the edges deviate from this in  
out serially. In order to achieve a clear relationship be- distance, the offset of the sine channel can be adjusted  
tween the calibration parameters which have an effect using VOSS. The same applies to the falling edges of  
on the analog sensor signals and the digital sensor val- the A signal which should also have a distance of half  
ues derived from these, the position of the zero pulse a period; deviations can be calibrated using the offset  
should be set to ZPOS = 0 so that the digital signal of cosine parameter VOSC. With parameter GCC the  
starting point matches that of the analog signals.  
distance between the neighboring flanks of signals A  
and B can then be adjusted to the exact value of an  
eighth of a cycle (a 45° angle distance).  
At an incremental resolution of 8 edges per revolu-  
tion (CFGRES = 0x1) those angle values can be dis-  
played at which calibration parameters VOSS, VOSC  
and GCC demonstrate their greatest effect. When ro-  
tating the magnet at a constant angular speed the in-  
cremental signals shown in Figure 16 are achieved,  
with which the individual edges ideally succeed one  
another at a temporal distance of an eighth of a cy-  
cle (a 45° angle distance). Alternatively, the angle po-  
sition of the magnet can also be determined using a  
reference encoder, rendering an even rotational action  
unnecessary and allowing calibration to be performed  
using the available set angle values .  
The various possible effects of parameters VOSS,  
VOSC and GCC on the flank position of incremental  
signals A and B are shown in Figure 16. Ideally, the  
Figure 16: Calibration using incremental signals  
 复制成功!