iC-LNG 16-BIT OPTO ENCODER  
WITH SPI AND SERIAL / PARALLEL OUTPUTS  
Rev A1, Page 23/25  
LED CURRENT CONTROL  
LCSET(5:0)  
Add. 0x06, bit 5:0  
LCSET(6) = 0  
0.240 Vp  
The optical receive power of the sine/cosine sensors  
Code  
0x00  
0x01  
...  
LCSET(6) = 1  
0.140 V  
is kept constant by the integrated LED control unit, re-  
gardless of the temperature and ageing effects of the  
LED. The type of control can be selected using param-  
eter LCSET(6), the possible options being sum control  
or square control. So that the internal interpolator is  
always optimally controlled in all operating conditions,  
square control should be used. Sum control should be  
used for signal conditioning.  
0.243 Vp  
0.24 Vp  
1i·0.0125  
1.1 Vp  
0.142 V  
0.14 V  
1i·0.0125  
0.640 V  
0x3F  
Table 29: Control Setpoint  
Error Monitoring  
LCSET(6) Add. 0x06, bit 6  
iC-LNG’s LED current control range is monitored.  
Should the LED current control exit its control range,  
internal error ERRS is set to 1. This error signal is or-  
gated with iC-LNG’s ERRP alarm (parity check) and  
output at error output ERR (cf. section on the alarm  
output).  
0
1
Square control (sum of the amplitude squares)  
Sum control (DC control prop. to VR())  
Table 28: Control mode  
The setpoint for the control can be configured using  
parameter LCSET(5:0).  
ALARM OUTPUT  
iC-LNG has an alarm or error output to indicate exist-  
ing errors. If an error occurs, pin ERR is set to 1.  
ER RO R ME SSA GE  
VD D  
ER R  
G ND  
iC-LNG’s LED current control range is monitored.  
Should the LED current control exit its control range,  
internal error ERRS is set to 1.  
ER RS  
ER RP  
³1  
If the parity check signals an error in the RAM area,  
internal error ERRP is set to 1.  
Figure 18: Alarm output  