型号: IBM11S1325LP-60T
PDF下载: 下载PDF文件 查看货源
内容描述: [EDO DRAM Module, 1MX32, 60ns, CMOS]
分类和应用: 动态存储器内存集成电路
文件页数/大小: 22 页 / 603 K
品牌: IBM [ IBM ]
 浏览型号IBM11S1325LP-60T的Datasheet PDF文件第3页浏览型号IBM11S1325LP-60T的Datasheet PDF文件第4页浏览型号IBM11S1325LP-60T的Datasheet PDF文件第5页浏览型号IBM11S1325LP-60T的Datasheet PDF文件第6页浏览型号IBM11S1325LP-60T的Datasheet PDF文件第8页浏览型号IBM11S1325LP-60T的Datasheet PDF文件第9页浏览型号IBM11S1325LP-60T的Datasheet PDF文件第10页浏览型号IBM11S1325LP-60T的Datasheet PDF文件第11页  
Discontinued (9/98 - last order; 3/99 last ship)
IBM11S1325LP IBM11S2325LP
1M/2M x 32 SO DIMM Module
AC Characteristics
(T
A
= 0 to +70
°
C, V
CC
= 3.3V
±
0.3V)
1. An initial pause of 200µs is required after power-up followed by 8 RAS only refresh cycles before proper device operation is
achieved. In case of using the internal refresh counter, a minimum of 8 CAS before RAS refresh cycles instead of 8 RAS only
refresh cycles is required.
2. AC measurements assume t
T
=2ns.
3. V
IH
(min.) and V
IL
(max.) are reference levels for measuring timing of input signals. Also, transition times are measured between V
IH
and V
IL
.
4. When both CAS0 & CAS1 or CAS2 & CAS3 go low at the same time, all 16 bits of data are read/written into the device. CAS0 &
CAS1 or CAS2 & CAS3 (CAS’
S
to the same DRAM) cannot be staggered within the same read/write cycle.
Read, Write, and Refresh Cycles
(Common Parameters)
-60
Symbol
t
RC
t
RP
t
CP
t
RAS
t
CAS
t
ASR
t
RAH
t
ASC
t
CAH
t
RCD
t
RAD
t
RSH
t
CSH
t
CRP
t
DZC
t
T
Parameter
Min
Random Read or Write Cycle Time
RAS Precharge Time
CAS Precharge Time
RAS Pulse Width
CAS Pulse Width
Row Address Setup Time
Row Address Hold Time
Column Address Setup Time
Column Address Hold Time
RAS to CAS Delay Time
RAS to Column Address Delay Time
RAS Hold Time
CAS Hold Time
CAS to RAS Precharge Time
CAS Delay Time from D
IN
Transition Time (Rise and Fall)
104
40
10
60
10
0
10
0
10
14
12
10
45
5
0
2
Max
10K
10K
45
30
30
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
1
2
Units
Notes
1. Operation within the t
RCD
(max) limit ensures that t
RAC
(max) can be met. t
RCD
(max) is specified as a reference point only: if t
RCD
is greater than the specified t
RCD
(max) limit, then access time is controlled by t
CAC
.
2. Operation within the t
RAD
(max) limit ensures that t
RAC
(max) can be met. t
RAD
(max) is specified as a reference point only: If t
RAD
is greater than the specified t
RAD
(max) limit, then access time is controlled by t
AA
.
75H1720
SA14-4472-01
Revised 6/97
©IBM Corporation. All rights reserved.
Use is further subject to the provisions at the end of this document.
Page 7 of 22