Nomenclature
HTG3XYZ yyy
Connector Type
Voltage Supply: 3 for 3.3 Volts
5 for 5 Volts
Mechanical Package: 1 for Housing 1 with screw/fastener mount capability
3 for Housing 3 with PTFE membrane
Output Type: 4 for Frequency
5 for Voltage
• SPECIFIC ELECTRICAL AND METROLOGICAL CHARACTERISTICS
Electrical Characteristics
HTG35Y3
Characteristics
Sym bol
M in
Typ
M ax
3.46
1.750
-
Unit
Voltage Supply (1) (2)
Vcc
Vout
3
3.3
1.695
+18
1.5
Vdc
V
Nominal Output @55%RH
1.640
-
-
Humidity Average Sensitivity (in continuous and pulsed mode)
Current consumption (in continuous and pulsed mode)
(1) Module is ratiometric to voltage supply
ꢂmV/RH
Icc
mV/%RH
mA dc
3.0
(2) Maximum power supply ramp up time to VCC should be less than 20ms
HTG35Y5
Characteristics
Sym bol
M in
Typ
M ax
Unit
Voltage Supply (1) (2)
Vcc
Vout
4.75
5
5.25
2.630
2.540
-
Vdc
V
Nominal Output @55%RH in pulsed mode
Nominal Output @55%RH in continuous mode
Humidity Average Sensitivity in pulsed mode
Humidity Average Sensitivity in continuous mode
Current consumption (in continuous and pulsed mode)
(1) Module is ratiometric to voltage supply
2.510
2.420
-
-
-
2.570
2.480
+26
+25
3.2
Vout
V
ꢂmV/RH
ꢂmV/RH
Icc
mV/%RH
mV/%RH
mA dc
-
(2) Maximum power supply ramp up time to VCC should be less than 20ms
________________________________________________________________________________________
Humirel HTG3500 Series Datasheet / HPC123 Rev B November 2007
3