欢迎访问ic37.com |
会员登录 免费注册
发布采购

HDMP-1034A 参数 Datasheet PDF下载

HDMP-1034A图片预览
型号: HDMP-1034A
PDF下载: 下载PDF文件 查看货源
内容描述: 发射器/接收器芯片组 [Transmitter/Receiver Chip Set]
分类和应用:
文件页数/大小: 32 页 / 249 K
品牌: HP [ AGILENT(HEWLETT-PACKARD) ]
 浏览型号HDMP-1034A的Datasheet PDF文件第1页浏览型号HDMP-1034A的Datasheet PDF文件第2页浏览型号HDMP-1034A的Datasheet PDF文件第3页浏览型号HDMP-1034A的Datasheet PDF文件第5页浏览型号HDMP-1034A的Datasheet PDF文件第6页浏览型号HDMP-1034A的Datasheet PDF文件第7页浏览型号HDMP-1034A的Datasheet PDF文件第8页浏览型号HDMP-1034A的Datasheet PDF文件第9页  
Setting the Operating Data Rate Range
The HDMP-1032A/1034A chipset
can operate from 260 MBaud to
1400 MBaud. It is divided into
three operating data ranges with
each range selected by setting
DIV1/0 as shown in the Typical
Operating Rates table. Two
examples have been provided in
order to help in understanding
and using this table.
Example 1 (Unique Range)
It is desired to transmit a 16 bit
parallel word operating at a fre-
quency of 60 MHz (60 MWord/
sec). Both the Tx and Rx must
be set to a range that covers this
word rate. According to the table
only a setting of DIV1/0 = (0/0)
allows a parallel input word rate
of 40 to 70 MHz. This range
setting easily accommodates the
required 60 MHz word rate and
is unique. The user serial data
rate is calculated as:
Serial Data Rate =
60MW
16bits
(–––––) (–––––) =
Word
sec
960 MBits/sec
The baud rate includes an addi-
tional four encoding bits (20 bits
total) that the HDMP-1032A/34A
G-Link chipset transmits. The
serial baud rate is calculated as:
Serial Baud Rate =
60MW
20bits
(–––––) (–––––) =
Word
sec
setting of DIV1/0 = (0/1) gives
an upper rate of 45 MHz while a
setting of DIV1/0 = (0/0) gives a
lower rate of 40 MHz. The upper
and lower data rates stated in the
tables are typical values unless
indicated by (min) or (max) and
may vary between individual parts.
However, each transmitter/receiver
has overlapping ranges of opera-
tion providing continuous band
coverage from 260 to 1400 MBaud.
In this example, each transmitter/
receiver will permit a 42.5 MHz
parallel data rate but it is sug-
gested that DIV0 be tied to a
jumper that can be set either to
logic ‘1’ (open allowing DIV0 to
float high) or logic ‘0’ (ground).
This allows the design to accom-
modate both ranges for maximum
flexibility. This technique is rec-
ommended whenever operating
near the upper and lower ends of
two adjacent word rate ranges.
1200 MBaud
Example 2 (Overlapping Ranges)
Some applications may have a
parallel word rate that seems
to fit in two ranges of opera-
tion. For example, a 42.5 MHz
(42.5 MWord/s) parallel data
rate falls within two ranges:
DIV1/0 = (0/0) and DIV1/0 =
(0/1). According to the table, a
HDMP-1032A (Tx), HDMP-1034A (Rx)
Typical Operating Rates
1,2
Tc = –20°C to +85°C, V
CC
= 3.15V to 3.45V
Parallel Word Rate
(MWord/sec)
DIV1
0
0
1
DIV0
0
1
40
20
Range
70 (max)
45
640
320
Serial Data Rate
(MBits/sec)
Range
1120 (max)
720
800
400
Serial Baud Rate
(MBaud)
Range
1400 (max)
900
Figure 2. Typical data rates showing ranges of operation
1
.
Notes:
1. All values in this table and graph are typical unless otherwise noted by (min) or (max), (min) indicates a minimum guaranteed value,
(max) indicates a maximum guaranteed value.
2. All values in this table are expected for a BER less than 10
-14
.
4
;;;;
;;;
;;;;
;;
;;
0
13 (min)
26
208 (min)
416
WORD RATE (MWords/sec)
50
5
25
75
0/0
0/1
1/0
800
400
900
260 (MIN.)
100
520
500
1000
1500
SERIAL BAUD RATE (MBaud)
260 (min) 520
100
DIV 1 / DIV 0
1400 (MAX.)
2000