Performance Characteristics (continued)  
Display System  
Display  
7-inch raster monochrome CRT  
Throughput of Analog Channels 25 million vectors/sec per channel with 32 levels of intensity  
Resolution  
255 vertical by 1000 horizontal points (waveform area) 32 levels of gray scale  
Waveform intensity on front panel. Vectors on/off; infinite persistence on/off 8 x 10 grid with continuous intensity control  
Key-specific help in 11 languages displayed by pressing and holding key or softkey of interest  
Time and date (user setable)  
Controls  
Built-in Help System  
Real Time Clock  
Measurement Features  
Automatic Measurements  
Voltage (analog channels only)  
Time  
Measurements are continuously updated. Cursors track current measurement  
Peak-to-Peak, Maximum, Minimum, Average, Amplitude, Top, Base, Overshoot, Preshoot, RMS (DC)  
Frequency, Period, + Width, - Width and Duty Cycle on any channels  
Rise time, Fall time, X at Max (Time at max volts), X at Min (Time at min volts), Delay, and Phase on analog channels only.  
Counter  
Built-in 5 digit frequency counter on any channel. Counts up to 125 MHz  
Threshold Definition  
Cursors  
Variable by percent and absolute value; 10ꢂ, 50ꢂ, 90ꢂ default for time measurements  
Manually or automatically placed readout of Horizontal (X, X, 1/X) and Vertical (Y, Y)  
Additionally digital or analog channels can be displayed as binary or hex values  
Waveform Math  
One function of 1-2, 1*2, FFT, differentiate, integrate.  
Source of FFT, differentiate, integrate: analog channels 1 or 2 (or 3 or 4 for 54624A), 1-2, 1+2, 1*2  
FFT  
Points  
Fixed at 2048 points  
Source of FFT  
Window  
Analog channels 1 or 2 (or 3 or 4 on 54624A only), 1+2, 1-2, 1*2  
Rectangular, Flattop, Hanning  
-70 to -100 dB depending on averaging  
In dBV, dBm@50 Ω  
Noise Floor  
Amplitude Display  
Frequency Resolution  
Maximum Frequency  
0.097656/(time per div.)  
102.4/(time per div.)  
*
Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ± 10 ꢀC from firmware calibration temperature.  