RF42/43  
6.4. Data Whitening, Manchester Encoding, and CRC  
Data whitening can be used to avoid extended sequences of 0s or 1s in the transmitted data stream to achieve a  
more uniform spectrum. When enabled, the payload data bits are XORed with a pseudorandom sequence output  
from the built-in PN9 generator. The generator is initialized at the beginning of the payload. The receiver recovers the  
original data by repeating this operation. Manchester encoding can be used to ensure a dc-free transmission and good  
synchronization properties. When Manchester encoding is used, the effective datarate is unchanged but the actual  
datarate (preamble length, etc.) is doubled due to the nature of the encoding. The effective datarate when using  
Manchester encoding is limited to 64 kbps. Data Whitening and Manchester encoding can be selected with "Register  
70h. Modulation Mode Control 1". The CRC is configured via "Register 30h. Data Access Control".  
6.5. TX Retransmission and Auto TX  
The RF42/43 is capable of automatically retransmitting the last packet in the FIFO if no additional packets were  
loaded into the TX FIFO. Automatic Retransmission is achieved by entering the TX state with the txon bit set. This  
feature is useful for Beacon transmission or when retransmission is required due to the absence of a valid  
acknowledgement. Only packets that fit completely in the TX FIFO are valid for retransmit. When it is necessary to  
transmit longer packets, the TX FIFO uses the circular read/write capability.  
An Automatic Transmission is also available. When autotx = 1 the transceiver will enter automatically TX State  
when the TX FIFO is almost full. When the TX FIFO is empty the transceiver will automatically return to the IDLE  
State.  
POR  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Add R/W Function/Description  
Def.  
Operating &Function  
R/W  
Reserved  
autotx  
Reserved  
Reserved  
ffclrtx  
00h  
08  
Control 2  
34  
Tel: +86-755-82973805  
Fax: +86-755-82973550  
E-mail: sales@hoperf.com  
http://www.hoperf.com  