RF42/43
1.1. Definition of Test Conditions
Production Test Conditions:
TA = +25 °C
VDD = +3.3 VDC
External reference signal (XIN) = 1.0 VPP at 30 MHz, centered around 0.8 VDC
Production test schematic (unless noted otherwise)
All RF input and output levels referred to the pins of the RF42/43 (not the RF module)
Extreme Test Conditions:
TA = –40 to +85 °C
VDD = +1.8 to +3.6 VDC
External reference signal (XIN) = 0.7 to 1.6 VPP at 30 MHz centered around 0.8 VDC
Production test schematic (unless noted otherwise)
All RF input and output levels referred to the pins of the RF42/43 (not the RF module)
Test Notes:
All electrical parameters with Min/Max values are guaranteed by one (or more) of the following test methods.
Electrical parameters shown with only Typical values are not guaranteed.
■ Guaranteed by design and/or simulation but not tested.
■ Guaranteed by Engineering Qualification testing at Extreme Test Conditions.
■ Guaranteed by 100% Production Test Screening at Production Test Conditions.
11
Tel: +86-755-82973805
Fax: +86-755-82973550
E-mail: sales@hoperf.com
http://www.hoperf.com