RF31
1.1. Definition of Test Conditions
Production Test Conditions:
TA = +25 °C
VDD = +3.3 VDC
External reference signal (XIN) = 1.0 VPP at 30 MHz, centered around 0.8 VDC
Production test schematic (unless noted otherwise)
All RF input and output levels referred to the pins of the RF31 (not the RF module)
Extreme Test Conditions:
TA = –40 to +85 °C
VDD = +1.8 to +3.6 VDC
External reference signal (XIN) = 0.7 to 1.6 VPP at 30 MHz centered around 0.8 VDC
Production test schematic (unless noted otherwise)
All RF input and output levels referred to the pins of the RF31 (not the RF module)
Test Notes:
All electrical parameters with Min/Max values are guaranteed by one (or more) of the following test methods.
Electrical parameters shown with only Typical values are not guaranteed.
■ Guaranteed by design and/or simulation but not tested.
■ Guaranteed by Engineering Qualification testing at Extreme Test Conditions.
■ Guaranteed by 100% Production Test Screening at Production Test Conditions.
11
Tel: +86-755-82973805
Fax: +86-755-82973550
E-mail: sales@hoperf.com
http://www.hoperf.com