MICRO SWITCH™ Premium Miniature Basic Switches  
Table 1. Specifications  
Characteristic  
Parameter  
Circuitry  
SPDT, SPNC, SPNO  
Operating force  
0,25 N to 3,9 N [15 g to 397 g]  
quick connect; 4,75 mm x 0,51 mm [0.187 in x 0.02 in]  
quick connect: 6,35 mm x 0,81 mm [0.25 in x 0.032 in]  
PCB (printed circuit board)  
Termination  
Actuators  
pin plunger, integral lever options, auxiliary lever options  
CSA, ENEC, UL; RoHS compliant  
Agency certification  
Operating temperature  
Mechanical life  
-40 °C to 85 °C [-40 °F to 185 °F], options for 175 °C [347 °F]  
up to 10 million cycles  
Contact material  
Housing material  
silver, gold plated, gold alloy  
high strength thermoplastic  
Table 2. Electrical Ratings  
Rating code  
UL, CSA  
ENEC3  
5 A 125 Vac, 250 Vac, 277 Vac  
1/10 HP 250 Vac  
A
3 (1) A, 250 Vac 2  
11 A 1/3 HP 125 Vac, 250 Vac or 277 Vac  
1/2 A 125 Vdc; 1/4 A 250 Vdc  
4 A 125 Vac “L” 1  
B
10 (3) A, 250 Vac 2  
15.1 A 1/2 HP 125 Vac, 250 Vac or 277 Vac  
1 /2A 125 Vdc  
C
E
1/4 A 250 Vdc; 5 A 125 Vac “L” 1  
10 A 1/3 HP 125 Vac, 250 Vac or 277 Vac  
1/2 A 125 Vdc  
5 (2) A, 250 Vac 2  
1/4 A 250 Vdc, 4 A 125 Vac “L” 1  
3 A 125 Vac, 250 Vac, 277 Vac  
1/10 HP 250 Vac  
F
S
V
W
Z
0.1 A, 125 Vac  
1 (0.05) A, 250 Vac 2  
16 (4) A, 250 Vac 2  
21 A 1 HP 125 Vac, 250 Vac, 277 Vac  
2 HP 250 Vac, 277 Vac  
15.1 A 125 Vac, 250 Vac, 277 Vac  
25 A, 277 Vac  
1 HP, 125 Vac; 2 HP, 250 Vac  
20 (5) A, 250 Vac 2  
1 Incandescent lamp rating  
2 XX(Y) - XX = max. rated resistive value in amps, and (Y) = max. rated inductive value in amps  
3 European ENEC rating requires Mounting Construction code “9” or “0”. See page four, Mounting Construction column  