Basic Switches
6 AS Series
Tandem Switch Assemblies
ORDER GUIDE
Le ve r
Le ngth
mm
O.F.
max.
newtons newtons
R.F.
min.
O.T.
min.
mm
D.T.
max.
mm
Ele ctrical
Data and
O.P.*
mm
Catalog
Type
Lis ting
De s cription
inche s Te rminals UL Code s
ounce s
ounce s
inche s
inche s
inche s
6AS13
Centered lever.
Adjustment over
switch D.
30,56
1.203
15 Amps
2,22
8
0,14
0.5
0,51
.020
2,77
.109
29,77
1.172
Solde r
Solde r
A2
A
6AS18
6AS36
Centered lever.
Adjustment over both
switches.
30,56
1.203
15 Amps
2,22
8
0,14
0.5
0,51
.020
2,77
.109
29,77
1.172 adj.
A
Lever over switch C.
Adjustment over
switch D.
30,56
1.203
15 Amps
2,22
8
0,14
0.5
0,51
.020
2,77
.109
29,77
1.172
A
6AS35
6AS16
Lever and adjustment 30,56
15 Amps
2,22
8
0,14
0.5
0,51
.020
2,77
.109
29,77
1.172
over switch D.
1.203
A2
A2
A
Centered lever.
Adjustment over
switch D.
30,56
1.203
20 Amps
3,89
14
1,11
4
1,02
.040
3,96
.156
30,96±1,14
1.219±.045
G
6AS69
Centered lever.
Adjustment over
switch D.
27,25
1.073
25 Amps
30,96±1,14
1.219±.045
T
M
—
—
—
—
6AS112 Centered lever.
Adjustment over
switch D.
30,56
1.203
25 Amps
3,89
14
1,11
4
1,02
.040
3,96
.156
30,96±1,14
1.219±.045
Dim. Dwg. Fig. 2
A2
H
6AS5
Centered leaf. No
adjustment. Switches
operate within .030⍯
of each other.
38,35
1.51
15 Amps
0,76-1,52
.030-.060
A2
A
—
—
—
Dim. Dwg. Fig. 3
Unless otherwise noted * ±0,76 mm
±.030 in.
MOUNTING DIMENSIONS (For reference only)
STRAIGHT LEVER
ROLLER LEVER
LEAF
Fig. 1
Fig. 2
Fig. 3
Mounting holes accept pins or screws of
.139 ⍯ (3,53 mm) diameter.
For application help: call1-800-537-6945.
Honeywell Sensing and Control 75