Basic Switches
6AS Series
Tandem Switch Assemblies
FEATURES
GENERAL INFORMATION
6AS switches are two standard basic
Choice of circuitries and electrical switches ganged together and actuated
ɀ
ɀ
Variety of actuators
ratings
Choice of terminations
by a single actuator. Operating character-
istics will depend on the type of individual
ɀ
ɀ
Field adjustable operating point on one switches and actuators.
or both basic switches
ELECTRICAL RATING
Ele ctrical Data and
UL Code s
Circuitry
Single-pole
double-throw
unless
otherwise noted
in order guide
A
G
15 amps, 125, 250 or 480 vac;
1/8 hp, 125 vac; 1/4 hp, 250 vac;
1/2 amp, 125 vdc; 1/4 amp,
250 vdc.
UL Code L96
Single-pole
double-throw
unless
20 amps, 125, 250 or 480 vac;
10 amps, 125 vac ‘‘L’’ (tungsten
lamp load);
otherwise noted
in order guide
1 hp, 125 vac; 2 hp, 250 vac;
1/2 amp, 125 vdc; 1/4 amp,
250 vdc.
UL Code L23
Characteris tics : O.F. – Operating Force; R.F. – Release Force; P.T. – Pre-
ORDER GUIDE
travel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position.
Le ve r
Le ngth
mm
O.F.
max.
newtons newtons
ounce s
R.F.
min.
O.T.
min.
mm
D.T.
max.
mm
Ele ctrical
Data and
O.P.*
mm
inche s
Catalog
Lis ting
Type
De s cription
inche s Te rminals UL Code s
ounce s
inche s inche s
6AS32 Centered lever. Adjustment over
58,72
15 Amps
2,22
0,14
0,51
2,77
18,29
both switches.
2.312
Solde r
Solde r
A2
A
8
0.5
.020
.109
.720 adj.
6AS54 Short lever. Adjustment over
20,47
.806
15 Amps
3,34
12
0,83
3
0,25
.010
3,96
.156
18,24
.718 max.
switch D.
A
6AS25 Centered lever. Adjustment over
32,26
1.270
20 Amps
3,89
14
1,11
4
1,02
.040
18,67
.735
Dim. Dwg. Fig. 1
switch D.
G
—
Unless otherwise noted * ±0,76 mm
±.030 in.
74 Honeywell Sensing and Control
For application help: call1-800-537-6945.