HRF-SW1000
DC Electrical Specifications @ + 25oC
Parameter
Single VDD Supply Voltage
Minimum
3.3*
Typical
Maximum
5.5
Units
V
5.0
CMOS Logic Level (0)
0
0.8
V
CMOS Logic Level (1)
VDD – 0.8
VDD
V
Input Leakage Current
10
uA
* Performance curves are for Vdd = +5.0 +/- 10%
Absolute Maximum Ratings1
Parameter
Absolute Maximum
Units
VDD
+6.0
V
Vin Digital Logic 0
Vss - 0.6
Vdd + 0.6
> 35
V
V
Vin Digital Logic 1
Maximum Input Power
ESD Voltage
dBm
400
V
Operating Temperature Range
Storage Temperature Range
+85
Degrees C
Degrees C
+125
(Note 1) Operation beyond any of these parameters may cause permanent damage.
Latch-Up: Unlike conventional CMOS RF switches, Honeywell's HRF-SW1000 is immune to latch-up.
ESD Protection: Although this device contains ESD protection circuitry on all digital inputs, conventional precautions should be
taken to ensure that the Absolute Maximum Ratings are not exceeded.
Package Outline Drawing
Bottom View
12 Pin 3X3 mm LPCCTM Package
3 mm
ASAT LPCC Marketing Outline Dwg. # GMJ00004
For more information see http://www.asat.com
3 mm
________________________________________________________________________________________________________
Web Site:
Email:
www.mysoiservices.com
mysoiservices@honeywell.com
Honeywell
Solid State Electronics Center
12001 State Highway 55
2002 1000W
Published June 2002 Page 2
Plymouth, Minnesota 55441-4799
1-800-323-8295