HI-3200, HI-3201  
ARINC 429 Received Data Interrupt Look-Up Table  
0x7BFF  
0x7BE0  
Label = 0xFF  
Label = 0xF8  
Label = 0x08  
Interrupt Look-Up Table  
Channel 7  
0x7B3F  
Interrupt Look-Up Table  
Channel 1  
0x7B20  
0x7B1F  
Label = 0x0F  
Label = 0x07  
Interrupt Look-Up Table  
Channel 0  
7
6
5
4
3
2
1
0
0x7B00  
Label = 0x00  
Label = 0x01  
ARINC 429 Received Data Status Byte Definition  
NEWTX0  
X
X
6
STATUS BYTE  
7
5
4
3
2
1
0
LSB  
MSB  
Bit Name  
R/W Default Description  
7
6
5
-
R/W  
R/W  
R/W  
0
0
0
Not used  
Not used  
-
NEWHOST  
This bit is set when a newARINC 429 word is received and stored in this block. It is reset when  
the host CPU executes SPI instruction 0xC0 - 0xFF to read the block.  
4
3
2
1
0
NEWCAN  
NEWTX3  
NEWTX2  
NEWTX1  
NEWTX0  
R/W  
R/W  
R/W  
R/W  
R/W  
0
0
0
0
0
This bit is set when a newARINC 429 word is received and stored in this block.It is reset when  
the CANTransmit scheduler reads any bytes from the block.  
This bit is set when a newARINC 429 word is received and stored in this block. It is reset when  
theARINC 429Transmit scheduler #3 reads any bytes from the block.  
This bit is set when a newARINC 429 word is received and stored in this block. It is reset when  
theARINC 429Transmit scheduler #2 reads any bytes from the block.  
This bit is set when a newARINC 429 word is received and stored in this block. It is reset when  
theARINC 429Transmit scheduler #1 reads any bytes from the block.  
This bit is set when a newARINC 429 word is received and stored in this block. It is reset when  
theARINC 429Transmit scheduler #0 reads any bytes from the block.  
HOLT INTEGRATED CIRCUITS  