Preliminary
HT9015
Electrical Characteristics
Ta=25°C
Test Conditions
Symbol
Parameter
Min. Typ. Max. Unit
VCC
Conditions
VCC
VCC1=VCC3
Operating Voltage
3.6
13.5
8.5
V
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
ICC1
ICC2
ICC3
ICC4
ICC5
ICC(A)
Current 1 Consumption
Current 2 Consumption
Current 3 Consumption
Current 4 Consumption
Current 5 Consumption
Current Alarm Supply
3.6V All on
mA
mA
mA
mA
mA
mA
3.6V RX-RF ON
3.6V RX-AF ON
3.6V TX-RF ON
3.6V TX-AF ON
3.5
2.1
1.7
3.6V
100
RL= 100kW
Supply Current in Battery
Saving Mode
ICC(BS)
3.6V All off
0
¾
¾
mA
IREF
VIH
VIL
IIH
VREF Voltage
3.6V
3.6V
3.6V
1.5
VCC3
0
V
V
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
Data Input Threshold
Data Input Threshold
Data Input Current
Data Input Current
CK Input Frequency
V
V
IH= VCC
IL= GND
¾
3.6V
3.6V
3.6V
0
mA
mA
IIL
V
0
fCK
38
1000 kHz
Regulator
Ta=25°C
Test Conditions
VCC Conditions
3.6V IOUT= 1mA
OUT= VREG
(Open)-0.05V
Symbol
Parameter
Min. Typ. Max. Unit
VREG
Output Voltage
1.7
2
3
2.3
V
V
IOUT (MIN)
Minimum Load Current
3.6V
mA
¾
¾
Detector
Ta=25°C
Test Conditions
Symbol
Parameter
Min. Typ. Max. Unit
VCC Conditions
VBAT-L
VBAT-H
VBAT-L
VBAT-H
Detection Voltage 1
Detection Voltage 1
Detection Voltage 2
Detection Voltage 2
3.6V
3.6V
3.6V
3.6V
3.3
3.37
3.15
3.2
V
V
V
V
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
6
April 10, 2000