HT48R063B/064B/065B/066B  
CALL addr  
Subroutine call  
Description  
Unconditionally calls a subroutine at the specified address. The Program Counter then in-  
crements by 1 to obtain the address of the next instruction which is then pushed onto the  
stack. The specified address is then loaded and the program continues execution from this  
new address. As this instruction requires an additional operation, it is a two cycle instruc-  
tion.  
Operation  
Stack ¬ Program Counter + 1  
Program Counter ¬ addr  
Affected flag(s)  
None  
CLR [m]  
Clear Data Memory  
Description  
Operation  
Each bit of the specified Data Memory is cleared to 0.  
[m] ¬ 00H  
Affected flag(s)  
None  
CLR [m].i  
Clear bit of Data Memory  
Description  
Operation  
Bit i of the specified Data Memory is cleared to 0.  
[m].i ¬ 0  
Affected flag(s)  
None  
CLR WDT  
Description  
Operation  
Clear Watchdog Timer  
The TO, PDF flags and the WDT are all cleared.  
WDT cleared  
TO ¬ 0  
PDF ¬ 0  
Affected flag(s)  
TO, PDF  
CLR WDT1  
Pre-clear Watchdog Timer  
Description  
The TO, PDF flags and the WDT are all cleared. Note that this instruction works in conjunc-  
tion with CLR WDT2 and must be executed alternately with CLR WDT2 to have effect. Re-  
petitively executing this instruction without alternately executing CLR WDT2 will have no  
effect.  
Operation  
WDT cleared  
TO ¬ 0  
PDF ¬ 0  
Affected flag(s)  
TO, PDF  
CLR WDT2  
Pre-clear Watchdog Timer  
Description  
The TO, PDF flags and the WDT are all cleared. Note that this instruction works in conjunc-  
tion with CLR WDT1 and must be executed alternately with CLR WDT1 to have effect. Re-  
petitively executing this instruction without alternately executing CLR WDT1 will have no  
effect.  
Operation  
WDT cleared  
TO ¬ 0  
PDF ¬ 0  
Affected flag(s)  
TO, PDF  
Rev. 1.00  
56  
April 7, 2011  
 复制成功!