HA16117F Series
Electrical Characteristics
(VCC = 5 V, Ta = 25°C, CF = 0.01 µF, CR = 0.1 µF, R1 = 510 kΩ, R2 = 750 kΩ)
Item
Symbol Min
Typ
Max
Unit
Test Conditions
General
Operating supply current
ICC1
ICC2
ISTBY
—
100
—
µA
VACC = 0 V,
fP-RUN = 100 Hz
—
200
600
µA
VACC = 0 V,
fP-RUN = 20 kHz
Standby supply current
—
43
100
4.5
µA
VACC = 12 V
When VCC drops
Low
Low voltage HA16117FPA/FPAJ VTL
4.3
4.4
V
voltage
detector
threshold
level
HA16117FPB/FPBJ
HA16117FPC/FPCJ
4.1
3.9
50
—
4.2
4.0
100
—
4.3
4.1
150
0.8
—
V
V
Hysteresis width
VHYS
mV
V
ACC
Low input voltage
High input voltage
Low input voltage
High input voltage
Power-on reset time
Reset-clock off time
Reset low time
VIL1
VIH1
VIL2
VIH2
tON
2.0
—
—
V
P-RUN
input
—
0.8
—
V
2.0
24
78
12
36
1
—
V
WDT
40
56
ms
ms
ms
ms
ms
ms
V
1
tOFF
tRL
*
130
20
182
28
Reset high time
tRH
60
84
P-RUN pin = 0 V
Low setup time
tSL
—
—
High setup time
tSH
—
—
1
RES
RES low voltage
VOL
VOH
—
—
0.4
—
IOL = 1 mA
Open
output
RES high voltage
Reset function starting voltage
Constant range of R1 and R2
—
VCC
0.8
0.6
V
VRES
K
—
1.4
0.8
V
Constant
range
0.55
—
K =R2 / (R1 + R2)
Operating supply voltage range
VCCRNG
VTL
—
6.0
V
Note: 1. Reset-clock off time tOFF is provided a shown in the under figure.
f = 500 Hz, Duty = 50%
P-RUN
RES
tOFF
5