HANBit
HFDOM40KVxxx
Recablibrate – 1Xh
Bit->
7
6
5
4
3
2
1
0
Command(7)
C/D/H(6)
1Xh
1
LBA
1
Drive
X
Cyl High(5)
Cyl Low(4)
Sec Num(3)
Sec Cnt(2)
Feature(1)
X
X
X
X
X
Recalibrate
This command is effectively a NOP command to the CompactFlash Storage Card and is provided for compatibility
purposes.
Request Sense – 03h
Bit->
7
6
5
4
3
2
1
0
Command(7)
C/D/H(6)
03h
1
LBA
1
Drive
X
Cyl High(5)
Cyl Low(4)
Sec Num(3)
Sec Cnt(2)
Feature(1)
X
X
X
X
X
Request Sense
This command requests extended error information for the previous command. Table 41 defines the valid extended
error codes for the CompactFlash Storage Card Series product. The extended error code is returned to the host in
the Error Register.
Extended Error Codes
Extended Error Code
Description
00h
No Error Detected
01h
Self Test OK ( No Error )
09h
Miscellaneous Error
20h
Invalid Command
21h
Invalid Address ( Requested Head or Sector Invalid )
Address Overflow ( address Too Large )
Supply or generated Voltage Out of Tolerance
Uncorrectable ECC Error
2Fh
35h , 36h
11h
URL:www.hbe.co.kr
Rev. 1.1 (December, 2003)
21 / 21
HANBit Electronics Co., Ltd.